SL24.D
Deceleration ramp
Deceleration ramp between normal and slow
down motor speed
P25
Soft ramp (minimum acceleration)
Steep ramp (maximum acceleration)
Flashing light during battery operation
P27
Flashing light not active in battery operation
Flashing light active during battery operation
Battery operation mode
Normal operation
P28
After an opening command the gate remains open
After the power goes off, the gate opens and
stays open
Dead-man operation
Dead-man not active
Emergency dead-man:
- In regular operating conditions, standard operation
- If safaties are engaged, dead-man operation
only on input 51 as a cycle command (open-
P29
close-open) no matter the setting for parameters
P03 and P18. Remote controls are disabled
Dead-man active:
- step-by-step command disabled, remote
controls disabled. The board accepts open and
close mantained commands only
Direction
Left-hand actuator (the gate, seen from the
side of the gate where the actuator is located
P31
opens to the left)
Right-hand actuator (the gate, seen from the
side of the gate where the actuator is located
opens to the right)
Remote control management
Remote control button programming on 1st
channel (step-by-step or open, see P18)
Waiting the code (press the remote control
button), the receiver is empty
Waiting the code (press the remote control
button), the receiver is set as rolling code
1CH
Waiting the code (press the remote control
button), the receiver is set as fixed code
Remote control button programmed on 1st
channel as 1st code in the memory
Remote control button programmed on 1st
channel as 55th code in the memory
Memorizzazione di un tasto sul 2° canale
(pedonale o uscita 12, vedere P20)
Waiting the code (press the remote control
button), the receiver is empty
Waiting the code (press the remote control
button), the receiver is set as rolling code
2CH
Waiting the code (press the remote control
button), the receiver is set as fixed code
Remote control button programmed on 2nd
channel as 1st code in the memory
Remote control button programmed on 2nd
channel as 55th code in the memory
Remote control button memory position check
Waiting the code (press the remote control
button), the receiver is empty
Waiting the code (press the remote control
button), the receiver is set as rolling code
Waiting the code (press the remote control
CTRL
button), the receiver is set as fixed code
Remote control button in position n.1 in the
memory on 1st channel
Remote control button in position n.99 in the
memory on 2nd channel
Button not in the memory
8
Remote control deletion
(8)
Use ▲▼ buttons to select the n. of the remote
control code to be deleted.
1
Code stored in position 3 in the memory as 1st
channel. Press OK to delete
8
ERAS
Code stored in position 3 in the memory as 2nd
(OFF)
channel. Press OK to delete
OFF
Memory position n. 3 free
ON
Deletion of all remote controls code from the
(0)
memory of the receiver. Press OK and hold for 5 s
to confirm
0
Setting the operating mode of the receiver of the control board:
1
The receiver of the control board operates in Rolling code mode or Fixed
2
code according to the first programmed remote control button:
- if the first programmed remote control button is Rolling Code, the re-
(0)
ceiver only accepts Rolling Code remote controls
0
- if the first programmed remote control button is Fixed Code, the receiver
only accepts Fixed Code remote controls
To change the receiver operating mode it is necessary to delete all the
remote controls in the memory (ERAS-ALL) and program the first remote
1
control according to the desired type
Factory reset
Display
Button
Msg
2
OK
oooo
Note:
(OFF)
Factory reset does not require performing a new gate travel calibra-
tion as it does not reset parameters P09-10-11-12-13-14-15-22-25-
OFF
31
Counters
Display
ON
Button
Msg
Msg
-
A025
display
ex.
▼
4075
In the example above, the gate has performed:
025 x (10000) + 4075 = 254075 total cycles
oooo
▼
P019
rc
▼
1234
In the example above, the gate has performed:
fc
019 x (10000) + 1234 = 191234 partial cycles
1001
OK
oooo
1055
Alarms history
Display
Button
Msg
oooo
rc
▲▼
X.FYY
fc
2001
-
1.F03
-
2. no
2055
OK
oooo
Protection level of the control board (default = OFF)
none
OFF
No protection
rc
1
Protection of menus PAR, DEF, LRNE and LRNA
2
Protection of menu RAD
fc
3
Full protection of the control board
1001
2099
no
EN
Description
Waiting to press OK for 5 s to load factory set-
tings
Description
First number of absolute cycles (multiplied by
10000)
Second number of absolute cycles
First number of partial cycles (multiplied by
10000)
Second number of partial cycles
By pressing OK for more than 5 s the control
board resets the count of the number of partial
cycles
Description
Use ▲ ▼ keys to scroll the alarms of the
control board in chronological order (last 9
memorized alarms, 1 most recent alarm, 9 old-
est alarm).
X indicates the position of the alarm, YY the
type of alarm (see the alarm list table)
In position 1 alarm 03 is present (see the alarm
list table)
In position 2 there is no alarm
Press OK until the display shows "oooo" to
clear the list of memorized alarms
-
1003
2003
3
ALL