• When sliding the probe into the probe housing, ensure that the probe is located more than ½ way into
the probe housing (refer Figure 6.17).
û
Probe not in
far enough
Figure 6.17
• Hand tighten the probe locking nut onto the probe housing, that will in turn tighten the washer onto
the o-ring (and create a seal).
• It is a good idea to periodically check the nuts securing the probes onto the manifold to ensure they
haven't come loose.
IMPORTANT: Ensure that the probe isn't inserted too far into the probe housing.
Pushing the probe against the inside of the probe housing (on the underside) risks
breaking the glass. Do not over tighten the probe locking nut onto the probe housing.
• Press
menu/setting select, the display then shows the pH set point (refer Figure 6.18);
The factory default pH set point is 7.4, however you may wish to change this once the Davey Lifeguard is
installed. It should be noted that Chlorine's effectivity is greatly influenced if pH levels are too high, or too
low. Davey recommends the pool chemistry levels shown in Section 10.
Figure 6.18
Adjustments to pH set point can be made as follows:
• Use the
menu up/down buttons to scroll to your desired set point;
• Once correct, then press
ü
ph set point:
-> 7.4
menu/setting select.
23
▲ CONTENTS
û
Probe in
too far