INSTALLATION
Installation
Making the water connection
Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
f Seal and insert the twin connectors.
f
3
3
2
1
1 Cold water with 3-way ball shut-off valve
2 DHW with tee
3 Gasket
f Fit the water connections.
f
1
2
1 Strainer
2 Plastic profile washer
f Fit the supplied strainer in the 3-way ball shut-off valve.
f
Material losses
!
The strainer must be fitted for the appliance to function.
f When replacing an appliance, check whether the
f
strainer is installed (see chapter "Installation / Main-
tenance").
www.stiebel-eltron.com
Fitting the cable grommet
1
1 Cable grommet
f Fit the cable grommet.
f
19
3 Nm
5 Nm
f Remove the transport protection plugs from the appliance
f
connections.
f Fit the appliance pipes with flat gaskets onto the twin
f
connectors.
Making the electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
Connection to the power supply is only permissible in the
form of a permanent connection in conjunction with the
cable grommet. Ensure the appliance can be separated
from the power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
Observe the type plate. The specified voltage must match
the mains voltage.
f Connect the power cable to the mains terminal (see the chap-
f
ter "Installation / Specification / Wiring diagram").
24
DHF-C |
23