Troubleshooting; Technical Specifications - Polar GH506 Manual De Instrucciones

Mostrar congelador
Ocultar thumbs Ver también para GH506:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
Telephone Helpline: 0845 146 2887 (United Kingdom)

Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the
Helpline.
Fault
The appliance is not
The unit is not switched on
working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The appliance turns
Too much ice on the condenser
on, but the
Condenser blocked with dust
temperature is too
high/low
Doors are not shut properly
Appliance is located near a heat
source or air flow to the
condenser is being interrupted
Ambient temperature is too
high
Unsuitable foodstuffs are being
stored in the appliance
Appliance is overloaded
Factory default parameters
adjusted
The appliance is
The appliance is not properly
leaking water
levelled
The discharge outlet is blocked
Movement of water to the drain
is obstructed
The water container is damaged Call POLAR agent or qualified Technician
The appliance is
Loose nut/screw
unusually loud
The appliance has not been
installed in a level or stable
position
The display lamp
Lamp needs replacing
does not illuminate

Technical Specifications

Model
Voltage
Power
GH507
230V
1100W
50Hz
GH506
230V
1000W
50Hz
Probable Cause
Temperature
Current
Range
5A
-18°C to -22°C
4.5A
-18°C to -22°C
Check the unit is plugged in correctly and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Defrost the appliance
Clean Condenser
Check doors are shut and seals are not damaged
Move the refrigerator to a more suitable location
Increase ventilation or move appliance to a cooler position
Remove any excessive hot foodstuffs or blockages to the fan
Reduce the amount of food stored in the appliance
Call POLAR agent or qualified Technician
Adjust the screw feet to level the appliance (if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if applicable)
Check and tighten all nuts and screws
Check installation position and change if necessary
Call POLAR agent or qualified technician
Capacity
Refrigerant
(litres)
920
R404a
412
R404a
Action
Dimensions
H x W x D
(mm)
1990 x 1370 x
720
1990 x 680 x
720
UK
Weight
(Kg)
212
138
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gh507

Tabla de contenido