TRANSPONDER MEMORISATION (CARD or KEY HOLDER)
- Remove cover - A - from the control unit.
- Insert card - B - code ACG9438 into one of the available slots.
- Press and hold down button - C - placing the transponder (CARD or KEY HOLDER) within
5 sec. on the reader as shown in figure - D - until hearing a "BEEP" indicating that
memorisation has been completed.
- Release key - C -.
- Repeat the operation for each transponder memorisation.
- Close the control unit cover - A -.
INDICATIONS
no "BEEP"
= transponder to be memorised.
1 "BEEP"
= transponder memorised.
2 "BEEPS"
= the memorisation of a transponder that is already memorised is repeated.
3 "BEEPS"
= after the annulment of a transponder.
4 "BEEPS"
= in "annulment" mode transponder not memorised.
CONNECTIONS AND PROGRAMMING FOR RFID READER
FOR AUTOMATIC SLIDER DOORS
- D -
CAUTION:
CONNECT A MAXIMUM NUMBER
OF 2 RFID READERS IN CARD - B -
(parallel connection).
CAUTION:
In
order
to
program
the
transponders, connect only one
RFID reader to card - B -.
Then connect the second RFID
reader.
CUT OFF POWER SUPPLY BEFORE
INSERTING THE CARD.
- C -
code ACG9438
B
5 "BEEPS"
= transponder reader memory full (maximum: 125 codes).
10 "BEEPS" = annulment of all the memorised codes.
ANNULMENT OF A TRANSPONDER
Press and hold down button - C - until a "CONSTANT BEEP".
Bring the transponder near (3 "BEEPS" confirming the annulment can be heard).
Release button - C -.
TRANSPONDER READER RESETTING
Reset the memory by annulling all the memorised transponders.
Press and hold down button - C - until the "CONSTANT BEEP" stops (10 "BEEPS" confirming
the total reset can be heard).
Release button - C -.