Programming – manual
Programming door calls
Remarks
• The call tone volume can be set
on the indoor device see operating
instructions.
1 Activate the programming mode
on the SNG 850-... Briefly press the
programming mode button, LED 1
flashes every 2 seconds.
3b Bus telephone
Lift the receiver at the bus telephone
which you wish to program. Hold
down the light button for 4 seconds.
A protracted acknowledgement
tone is audible in the receiver as
confirmation. The bus telephone is
now in the programming mode. Do
not replace the receiver until after
programming has been completed
at the bus telephone.
• For information on activating bus
indoor devices not mentioned here,
please refer to the Siedle In-Home
bus system manual, which can be
found in the Download area at
www.siedle.com.
2 Siedle custom-fit door loud-
speaker
In the case of the BTLE 050-... the
programming mode is activated
using the programming button. Next
to the terminal, hold down the pro-
gramming button for 4 seconds until
a protracted signal tone is audible.
4 On the door station, press and
hold the desired call button for
4 seconds until a sustained tone can
be heard from the door loudspeaker.
The call button is now assigned to
the bus indoor device.
3a Siedle Basic
Hold down the speech button for
4 seconds. A protracted acknowl-
edgement tone sounds as confirma-
tion and the muting LED begins to
flash. The bus indoor device estab-
lishes the speech connection to the
door station. The bus indoor device
is now in the programming mode.
4 Sek.
5 The call button is now firmly
assigned to the bus indoor devices.
Program additional users using the
same procedure or quit the pro-
gramming mode.