Transport; Storage; Care And Maintenance; Troubleshooting - Kärcher IVC 60/30 Tact2 Lp Manual De Instrucciones

Ocultar thumbs Ver también para IVC 60/30 Tact2 Lp:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36

Transport

CAUTION
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
 Release the park brakes and push the
appliance by the push handle.
 Grab the appliance by the chassis, not
by the sliding bow to load it.
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Storage

CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

Care and maintenance

DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Exchanging the flat pleated filter
Note: 2 persons are required to remove the
suction head.
 Release and remove the suction head.
 Release and remove the filter cover.
 Replace the flat pleated filter.
 Insert and lock the filter cover.
 Insert the suction head carefully, align
and lock it.

Troubleshooting

DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Suction turbine does not run
 Check the receptacle and the fuse of
the power supply.
 Check the power cable and the power
plug of the device.
 Turn on the appliance.
Vacuum turbine is running but the
machine is not sucking in dust/dirt
Note: With correct direction of rotation a
strong airflow can be felt out of the opening
of the exhaust muffler. Air is suctioned with
incorrect rotation direction.
Illustration
 Check the direction of rotation of the
motor. Exchange the poles on the appli-
ance plug if the rotation direction is
wrong.
Suction capacity decreases
 Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
 Check the suction head and the dispos-
al system for proper seating.
 Replace the flat pleated filter.
Dust comes out while vacuuming
 Lock the filter cover.
 Check the proper installation position of
the flat fold filters.
 Replace the flat pleated filter.
Automatic filter cleaning is not
 Suction hose is not connected.
 Suction hose used is too short (< 3m) or
the diameter is too large.
 Inform Customer Service.
Automatic filter cleaning cannot be
 Inform Customer Service.
– 4
EN
working
switched off
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

15761150

Tabla de contenido