Specifications And Operator Interface; Specifications - Mettler Toledo IND256x Guía Rápida

Ocultar thumbs Ver también para IND256x:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35

2. Specifications and Operator Interface

Specifications

Enclosure Type
Dimensions (l × w × d) 173 x 230 x 127 mm [6.8" x 9.1" x 5.0"]
Operating Environment
Power
Display
Weight Display
Scale Types
Number of Cells
Number of Scales
Load Cell Excitation
voltage
Keypad
Communication
Metrology
Approvals
30518693
|
04
|
03/2020
Stainless steel, configurable as desk top or column/wall mount enclosure
Operating temperature range:
Relative Humidity:
AC:
Operates at 187 VAC–250 VAC, 50/60 Hz and includes a power cord configured for the
country of use
DC:
18-30 VDC
Intrinsically safe external power supply: APS500/501 or NiMH Ex Battery Pack
25 mm height character, 240 x 96 pixel backlit LCD. Display update rate: 10 Hz
Maximum displayed resolution of 100,000 divisions
Analog load cells
Up to four 350 ohm load cells(2 or 3 mV/V)
One
4.5 VDC
26 keys: Zero, Tare, Clear, On/Off, Print, numeric and navigation keypads
Standard
One intrinsically safe serial port included on main board
Alibi memory
Storage for up to 60,000 records
Interface options
Intrinsically safe 4-20 mA analog output module or
Intrinsically safe active loop or
Intrinsically safe passive current loop
Serial Inputs: ASCII commands for Clear, Tare, Print, Zero, SICS (level 0 and level 1
Protocols
commands)
Serial Outputs: Toledo continuous output, command print output (5 configurable
templates), SICS command and report print
Europe: OIML R76; Class III, 6000e; TC10878
Global: OIML R76; Class III, 6000e; R76-2006-A-NL1-18.27
US: Class III/IIIL, nmax=10,000; CC No.: 18-099
Canada: Class III/IIIHD, nmax=10,000; AM-6115
ATEX /
Non Wi-Fi version
IECEx
Factory-configured WiFi
version
ATEX Certificate No.:
IECEx Certificate No.:
FM
Non Wi-Fi version
Factory-configured WiFi
version
FMus Certificate No.:
FMc Certificate No.:
-10 °C to +40 °C / Storage temperature range:
10-95%, non-condensing.
AC and DC version:
II 2G Ex eb ib [ib] mb IIC T4 Gb
II 2D Ex tb [ib] IIIC T60°C Db
-10°C ≤ Ta ≤ +40°C
AC and DC version:
II 2G Ex eb ib [ib] mb IIB T4 Gb
II 2D Ex tb [ib] IIIC T60°C Db
-10°C ≤ Ta ≤ +40°C
BVS 17 ATEX E 076 X
IECEx BVS 17.0064X
Only available with intrinsically safe external power supply or battery:
IS CL I,II,III/DIV 1/GP ABCDEFG/T4
CL I, Zone 1 AEx/Ex ib IIC T4 Gb
Zone 21 AEx/Ex tb [ib] IIIC T60°C Db
Only available for intrinsically safe external power supply or battery:
IS CL I,II,III/DIV 1/GP CDEFG/T4
CL I, Zone 1, AEx/Ex ib IIB T4 Gbs
Zone 21, AEx/Ex tb [ib] IIIC T60°C Db
FM18US0258X
FM18CA0123X
METTLER TOLEDO IND256x Terminal Quick Guide
-20 °C to +60 °C
Battery version:
II 2G Ex ib IIC T4 Gb
II 2D Ex tb [ib] IIIC T60°C Db
-10°C ≤ Ta ≤ +40°C
Battery version:
II 2G Ex ib IIB T4 Gb
II 2D Ex tb [ib] IIIC T60°C Db
-10°C ≤ Ta ≤ +40°C
3

Publicidad

Tabla de contenido
loading

Tabla de contenido