With a glance at the tester you can determine whether the liquid, e.g.
Coolant Scale, on left propylene glycol*, on right ethylene**
containssufficientantifreeze.Thedisplayofthedeviceisdividedintothreeseparate
scalesonwhichthevalueforeachliquidcanbereadoff.
*
Propylenes are primarily used as antifreeze outside Europe.
** Ethylenes are primarily used as antifreeze in Europe.
For the battery acid, the acid density is measured in kg/l. The scale shows the ranges
for Recharge=refill,Fair = acceptable and Good = good.
Exercisecautionwhentestingthebatteryacid:Acidmaynotcomeintocontactwith
the eyes or skin – health danger!
AdBlueisasyntheticallyproduced32.5percentsolutionofhighlypureHarnstoffin
demineralisiertem Wasser. Below 32.5 % the solution does not have an optimum
mixingratio.From32.5%thecompositionisreferredtoasideal.
• C heckwhetherprismandcoverontesterareclean.
• P laceonedropoftheliquidtobetestedontheprismwiththeincludedpipette
• C losecovertodistributedrop
• A djustfocusofeyepiecebyturning
• R eadoffvaluefromcorrespondingscale–aclearLight-Dark dividing line
appears
• A ftercompletingthetestprocedure,theprismmustbecleanedcarefullywithadry
cloth.
BDA_Frostschutz-Batteriesaeurepruefer.indd 6
Frost protection tester
Battery acid tester
AdBlue tester

Test procedure