Annex
Additional UL requirements
Installation
For a complete safe and vault installation connect to 'high security
cable'. This product shall be installed in accordance with The Ca-
nadian Electrical Code, Part 1, Safety Standard for Electrical In-
stallations.
Programming
The reduction of the sensitivity by the remote signal (terminal 7) is
not verified by UL.
Sensitivity settings verified by UL for Monolithic Concrete:
Minimum thicknessMaximum spacing Mode and
Meters
Feet
Meters
2.5
0.6
1.98
4.0
5.0
For coverage of surfaces over corners, the recommended spac-
ing is reduced by 75%.
Sensitivity settings verified by UL for Modular Steel Panels:
Minimum thicknessMaximum spacing
Meters
Inches
Meters
1.0
0.015
0.6
1.5
2.0
A detector shall be on each modular wall panel that is not con-
tinuously welded.
For coverage of surfaces over corners, the recommended spac-
ing is reduced by 75%.
Sensitivity settings verified by UL for Steel Safes:
Minimum
Place-
thickness
ment
Meters Inches Meters Feet
Body
0.006 0.25
Door
Body
0.006 0.25
Door
Body
0.006 0.25
Door
At least one detector is to be mounted on the door and at least
one detector is to be mounted on the body.
* Note: Shock sensitivity is defined as the sensitivity to single
impacts on the detector or its base. Only in USER MODE,
the shock sensitivity can be set independently of Mode
and Operating radius with the help of the ISN-SMS-W7
SensTool software. If one of the fixed DIP setting is used,
the shock sensitivity corresponds to Mode and Operating
radius as indicated in the tables above.
ISN-SM-80_008739_i_-_-
Anhang
Annexe
Operating
Feet
radius
Concrete
8.2
2.5m
Concrete
13.2
4m
Concrete
16.5
5m
Mode and
Operating
Feet
radius
Steel
3.3
1 m
Steel
4.9
1.5 m
Steel
6.6
2 m
Maximum
Mode and
spacing
Operating
radius
Steel
1.0
3.3
1 m
Steel
1.5
4.9
1.5 m
Steel
2.0
6.6
2 m
Appendice
Omologazione IMQ CA12.00766
Specifiche tecniche
Livello di prestazione ................................................. II° livello
Temperatura di funzionato .......................... +5 ºC fino a +40 ºC
Grado di protezione ..........................................................IP3X
l'assorbimento di corrente ................................................ 4 mA
immunità ai campi elettromagnetici10V/m 0.08 ............... 1GHz
Accessori non sono coperti dalla certificazione:
set da incasso ................................................. ISN-GMX-W0
scatola da pavimento ........................................ ISN-GMX-B0
Shock Sen-
scatola impermeabile .................................. ISN-GMXW-G0H
sitivity *
Emisor de ensayo ............................................. ISN-GMX-S1
Generador externo de test ................................ ISN-GMX-S5
High
Accessori
Disposizione di prova ISN-GMX-S1 ........................... I° livello
High
Piastra copritoppa ISN-GMX-P3S ISN-GMX-P3Z....... I° livello
High
Shock Sen-
sitivity *
Low
Fixation
Toutes les exigences relatives aux agréments nationaux et con-
Mid
cernant l'application du produit doivent être satisfaites.
Câblage du détecteur
Mid
Le câblage peut être réalisé avec du câble souple de 0,22 mm ou
du câble de type SYT.
Accessoires
ISN-SMS-W7 Feuille anti-perçage
Cette option n'est pas disponible en France.
Shock Sen-
ISN-GMX-WO Jeu pour encastrement mural avec couvercle
sitivity *
mode de protection selon (EN60529).............................. IP51
capabilité max. de porter du couvercle.................... .......25 kg
Low
Mid
GMXBO Boite de sol
mode de protection selon (EN60529).............................. IP51
Mid
capabilité max. de porter du couvercle................. ...... 1000 kg
Caractéristiques techniques
Tension d'alim: 8,0Vcc ....... 16Vcc; ondulation résidu..: 0,25 Vac
Bande de fréquences :........................................13 à 19 KHz
protection du boîtier (EN60529, EN50102) ...............IP43, IK07
Certification NFA2P type 3 N° 2730000340
Référentiel NF324-H58
ISN-SM-80
ISN-GMX-S1
ISN-GMX-P0
ISN-GMX-WO
ISN-GMX-B0
ISN-GMX-C2
ISN-SMS-W7
Organisme certificateur :
CNPP: www.cnpp.com
AFNOR: www.afnor.org
- 13 -
Anexo
Requisiti supplementari dell'IMQ
Exigences supplémentaires de NFA2P
273034-00
302302-02
302302-03
302302-08
302302-09
303303-02
273034-06