Ideal LinkMaster PRO XL Instrucciones página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 8
ND 3867-1 LinkMaster PRO XL Ins
DESCRIPTION
The LinkMaster
Pro XL can be powered on by pressing any of the four buttons. LinkMaster
powers off automatically after 5 minutes of continuous testing of a single cable. Disconnecting the cable
restores the tester to normal function. Most power-on modes will timeout in 20 minutes. The tone mode
will power off after 2
1
hours. The LinkMaster
2
off. The back light is toggled on and off by holding down SEL for 2 seconds or more. At power on, the
back light is always off. The back light turns off automatically 3 minutes after being turned on. (with or
without test activity)
Upon completion of the test, the wire map, ID and any faults are displayed.
• The top line of numbers on the display represents the connector pins on the main unit.
• The second line of pin numbers is the connector pin numbers of the remote.
• If there is a miswire, the numbers on the second line will indicate the pin numbers detected.
• If no connection was detected for some of the pins, the second line will be blank in those pin locations.
• If a short is detected, the second line will have a flashing 'x' in that position, and the specific short
condition displayed on the third line.
• If a split pair is detected, the pins affected will flash on the second display line. The specific split
condition will be displayed on the third line.
• If there are multiple errors to display on the third line, the messages will be displayed in sequence
until all are displayed.
• Under "ID", the number of the remote being used will be displayed.
Note: Connecting a coax remote to the LinkMaster
the second line of the display will be blank. To use the coax remotes, the LinkMaster
on and in the coax test mode as described below.
There are five modes of operation as described below plus a setup function. In any mode, pressing the
MODE button causes the mode select screen to be displayed. The OFF message is usually the first one
displayed. Continued pressing of the MODE button will cycle through the other modes. Pressing the
SEL button causes the currently displayed mode to be entered.
Cable Test – If there is no remote, press any of the buttons to turn on the LinkMaster
tester will then test for shorts, opens, and split pairs. The results are displayed as messages on the
LCD. Whenever a new cable assembly is inserted for testing, press the SEL button to start a new test
cycle. Partial and erroneous results can occur if not done.
Typical Cable Parameters
Cable
pF/ft
Data
CAT3
19.0
CAT5/5E
15.0
CAT6
15.0
Coax
RG6/U
16.25
RG11/U
16.25
RG58/U
27.5
RG59/U
16.25
Length – The length mode measures the length of a cable by measuring its capacitance and using the
capacitance per unit of length (length constant) to calculate the length. The length is displayed on the LCD
along with the current value of the length constant. The SEL button changes the pair being measured in
a 1-2, 3-6, 4-5, 7-8 and auto-select sequence. The pair number is displayed next to the length except
in auto-select mode. If a selected pair has a fault, the fault replaces the length reading on the LCD. In
auto-select mode, the LinkMaster
or 1-2 pair settings to measure the length of a coax cable connected to the F-connector. The length
constant is changed with the up and down arrows. The CAL icon is on while adjusting the constant.
Note: If the far end of the cable is connected to a Network Device (Hub, Switch, etc.), the LinkMaster
Pro XL will display "T Ring Network??", "xbase-T Network?" or "Network?" (based on the number of
conductors terminated into the device).
2/19/04
3:51 PM
Pro XL will turn on in the last mode used before turning
Pro XL with the unit off will power up the unit but
Typical Cable Parameters
pF/m
Cable
62.5
Security Wire
49.0
22 AWG, Jacketed
49.0
22 AWG, Unjacketed
53.0
20 AWG, Unjacketed
53.0
18 AWG, Unjacketed
90.0
53.0
Pro XL automatically selects a pair without a fault. Use the auto-select
3
Page 3
Pro XL
Pro XL must be
Pro XL. The
pF/ft
pF/m
24.0
78.5
14.0
46.0
16.0
52.5
17.0
55.0

Publicidad

Tabla de contenido
loading

Tabla de contenido