DURAVIT DuraSystem WD1022 Instrucciones De Montaje Y Uso página 6

Bastidor de pared estándar
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1
23 ¼"
≥5 ⅛"
>
Carrier must be installed in a constructed
2 x 6" wood or metal frame.
>
Studs must be placed 23-¼" apart
(clearance) from where the carrier will be
positioned inside the wall.
>
For 3-½" wall thickness vertical drainage only.
>
For 5-⅛" min. wall thickness RH, LH and vertical
drainage possible.
3
4
12
Variant 1: Wooden frame
Variant 2: Metal frame
6
70300131_Mounting_Wall carrier_standard
2
13 mm
1000 mm
39 ⅜"
> Carrier can be adjusted to accommodate drain from 8-⅝" - 9-½" from finished
floor.
> Determine the height needed and set prior to install.
> Adjust hight by changing the pin setting in the carrier foot.
4
13
20
> Observe the position of the drain.
> If the height of the toilet frame is
set on the reference marker, the
height of the drain is 8-⅝".
> Mark the location for the 3" DWV
waste pipe and the finished floor
(FF) to ensure proper clearance.
> Refer to the toilet bowl's Technical
Specifications to confirm.
220 mm
8 ⅝"
0 - 240 mm
0-9 ½"
5
FF
> Position carrier in frame to level.
> Adjust feet height as needed.
3
2
1