SAFETY INFORMATION
• Never operate the unit if the housing is defective!
• Never operate the unit if any electrical cables are
defective!
• Never carry or pull the unit by the electrical cable.
• Route cables such that they are protected from
damage and do not present a tripping hazard.
• Only open the unit housing or its attendant compo-
nents if this is explicitly specified in the operating in-
structions.
• Only carry out work on the unit that is described in
this manual. If problems cannot be overcome,
please contact an authorised customer service point
or, if in doubt, the manufacturer.
• Only use original spare parts and accessories for the
unit.
• Never carry out technical changes to the unit.
• Only connect the unit if the electrical data of the
unit and the power supply correspond. The unit
data is to be found on the unit type plate, on the
packaging or in this manual.
• When using heaters, ensure that they are approved
for use in the aquarium and that they do not come
into contact with the acrylic wall of the aquarium.
Suitable heaters meet the requirements in ac-
cordance with EN 60335-2-55.
• Protect the plug connection from moisture.
• Only connect the unit to a correctly fitted socket.
Symbols used in these instructions
Warnings
The warning information is categorised by signal
words, which indicate the extent of the hazard.
W A R N I N G
• Indicates a possibly hazardous situation.
• Non-observance may lead to death or serious inju-
ries.
N O T E
Indicates information intended to give the user a bet-
ter understanding.
Additional information
A Reference to a figure, e.g. Fig. A.
PRODUCT DESCRIPTION
• Check that the delivery scope is correct, complete
and undamaged.
A
biOrb HALO
1
Operating instructions biOrb HALO
2
Cover with cover ring and product-specific lighting
unit
3
Air column
4
Air hose with integrated non-return valve
5
Aerator pump with connection cable
6
Plug-in transformer
7
Ceramic substrate
− Quantity is product-specific
8
Bag with Water Conditioner and/or Biological
Booster
9
Filter unit
W A R N I N G
Danger of suffocation.
Keep plastic bags and small parts out of reach of babies
and young children.
Intended use
biOrb HALO may only be used as follows:
• As an aquarium.
The supplied components may only be used for the bi-
Orb products as specified in the following:
• The aerator pump: For aeration and supplying oxy-
gen to the aquarium.
• The lighting unit: For lighting the aquarium.
The following lighting units are approved for lighting
the biOrb HALO aquarium:
• biOrb HALO 30 LED
• biOrb HALO Moonlight LED
• biOrb HALO 15 MCR LED
• The plug-in transformer: For connecting the aerator
pump and lighting unit to the mains.
• Operation under observance of the technical data.
The following restrictions apply to the aquarium and
its components:
• Only operate with water at a water temperature of
+4 °C to +35 °C.
Function description
Aquarium with LED lighting, filter unit and external
aerator pump for circulating the water.
The light colour depends on the lighting unit used and
can be white, coloured, continuous or automatically
changing.
All lighting units can be programmed with the excep-
tion of the biOrb HALO 30 LED.
biOrb HALO 30 LED
• Daylight: White LEDs are continuously lit
biOrb HALO Moonlight LED
• Daylight: White LEDs are continuously lit
• Moonlight: Blue LEDs are continuously lit
• Automatic: Automatic change between daylight and
moonlight, depending on the amount of light pre-
sent
biOrb HALO 15 MCR LED
• White light or individually set coloured light, which
can be set and dimmed by remote control.
- EN -
19