ELECTRICAL CONNECTION

Before making any operation, you have to make sure that the general electric board, to which the unit is
connected, has a safe connection to the earth circuit and a suitable protection, as required by the regulation in
force in the country where the unit is installed. The outlet to which the unit will be connected must be such as to
support the absorbed power up to a maximum of 800W. Make sure that the mains voltage and the frequency
match the values indicated on the unit's plate. The unit is equipped with single-phase cable with plug. Connect
the cable to the unit on one side and to the outlet on the other.
INDIVIDUAL PROTECTION DEVICES
NOTICE!
DURING THE INSTALLATION AND USE OF THE UNIT, IT IS FORBIDDEN TO OPERATE WITHOUT THE
DEVICES MENTIONED BELOW.
The following signals summarize the protection devices to wear: protective gloves and goggles.
USE
To turn the unit on, use the switch on the left side of the unit.
The system of evacuation of possible residual gases will start automatically.
Check that all the scales are placed on "0" value. Otherwise, proceed with the scales zero-setting procedure
(service menu):
-
Press the Service key
-
Select "Scales zero-setting"
-
Digit password 9376
-
Do not move the unit during the zero-setting phase
-
Language selection: Press Service button and select language
Once the procedure is completed, go back to standby and start working with the unit.
1. Introduce refrigerant into the internal bottle
2. Introduce oil/UV additives into the oil reservoir
Start with Automatic or Manual function:
Recovery vacuum oil/UV batch refrigerant batch