FEATURES
Alarms
The alarm is triggered when the wind speed reaches or exceeds the
programmed value. It includes a configurable delay to prevent the
alarm from being triggered by gusts of winds.
The alarm is deactivated when the wind speed drops below the
programmed value. It also has a configurable delay to prevent the
alarm from being deactivated by temporary periods of low-intensity
wind.
The activation of ALARM2 deactivates ALARM1. When ALARM2 is
activated, the reading will blink to warn about the danger.
Alarms configuration: Trigger values, polarity, intermittent or
continuous alarm, alarm latching (only ALARM2)
Alarms outputs: Relays. Contacts "NO" and "NC" (ALARM1), contact
"NO" (ALARM2). Dry contact relay contacts.
User Default Setting
The setting can be saved as "User Default Setting" and can be
retrieved when necessary P00 – (3). If no configuration has been
saved, the factory configuration can be reset with this process.
Register of minimum and maximum wind values
WM44 automatically records the "Minimum" and the "Maximum"
wind speed value.
To access the programming buttons, insert a flat-headed screwdriver
into the groove marked as "Open to program" and lever the front
cover out.
Press "ENTER" to the see the "Minimum" value and press it again
to see the " Maximum" one. After 3 seconds it will automatically
display the current wind speed again.
PROGRAMMING
To access the programming buttons, insert a flat-headed screwdriver
into the groove marked as "Open to program" and lever the front
cover out.
To enter the "Programming Mode" press simultaneously "ENTER"
and "ESCAPE" for 2 seconds.
FUNCTIONS OF THE KEYS IN PROGRAMMING MODE
Button
Function
UP
Increases the program steps (P00, P01...), as well as
the options or values to be programmed.
DOWN
Decreases the program steps and the options or
values to be programmed.
ENTER
Enters the program step which validates options and
values and exits the program step.
ESC
Returns to the program steps.
Select the digit to be modified within the range.
WM44-P V3 / WM44-DRM V3
PROGRAM STEPS
P00
(1) Exit program mode without saving data,
(2) Exit program mode saving data,
(3) Exit program mode aplying "preset user configuration,
(4) Exit program saving data as "preset user configuration"
data by pressing "ENTER" for more than 10sec.
P01
(0) Programming in km / h,
(1) Programming in MPH,
(2) Programming in m / s. [0]
P02
Reference speed value. (1-999) [100]
P03
Hz corresponding to the reference speed value P02. (1-999)
[121]
P04
Speed-Hz ratio offset (0-999) [3]
P05
ALARM1.
(0) Disabled,
(1) OUT1 Relay closes NO contact ,
(2) OUT1 Relay opens NO contact. [1]
P06
ALARM1. Trigger value (1-999). [50]
P07
ALARM1. Mode.
(0) Continuous mode,
(1) Intermittent mode. [1]
P08
ALARM1. Only for intermittent mode (P07 = 1). Alarm ON
time in tenths of seconds (1-99). [10]
P09
ALARM1. Only for intermittent mode (P07 = 1). Alarm OFF
time in tenths of seconds (1-99). [50]
P10
ALARM2 operation,
(0) Disabled,
(1) OUT2 Relay closes contact,
(2) OUT2 Relay opens contact. [1]
P11
ALARM 2. Same as P06 ALARM ALARM1. [70] (when this
value is exceeded, the displayed value blinks as a warning).
P12
ALARM2. Same as ALARM1 P07. [0]
P13
ALARM2. Same as ALARM1 P08. [5]
P14
ALARM2. Same as ALARM1 P09. [5]
P15
ALARM2. Configuration latching.
(0) Non-latching,
(1) Latching [0] (Power off to release).
P16
Analogue output (only for those devices that have it).
(0) Disabled, (1-999) Wind speed value corresponding to the
highest value of the 10V or 20mA analogue output.
P17
ALARM1. Activation delay in seconds (0-999). [2]
P18
ALARM1. Deactivation delay in seconds (0-999). [5]
P19
ALARM2. Activation delay in seconds (0-999). [2]
P20
ALARM2. Deactivation delay in seconds (0-999). [5]
Notes:
- In bold and between brackets [x], the factory settings.
-Preconfigured factory values in compliance with ITC MIE-AEM-2:
· Wind speed sensor model: Anemo 4403.
· ALARM1 is triggered at 50km/h, ALARM1 activation closes the relay contact,
ALARM1 is intermittent (ton=1sec, t=5 sec).
· ALARM2 is triggered at 70km/h. ALARM2 close contacts NO. ALARM2 is
continuous.
-Users may program WM44P to comply with local safety regulations.