• Before taking any measurements, make sure that both
the area to be tested (e.g. a line), the test device and
the accessories used (e.g. connection cable) are in proper
working order. Test the device by connecting it to known
voltage sources (e.g. a 230 V socket in the case of AC
testing or a car battery in the case of DC testing).
• The device must be disconnected from all power sources and
measuring circuits before opening the cover to change the
battery(ies) or fuse(s).
• Observe the safety precautions of local and national
authorities relating to the correct use of the device and any
prescribed safety equipment (e.g. electrician's safety gloves).
• The device must not be connected to voltages for longer
than 30 seconds.
• The device is not suitable for unsupervised use.
• If you have to take hold of the measuring spikes, do so by
the grip sections only. Do not touch the measuring contacts
whilst the measurement is being taken.
• Do not work alone in the vicinity of hazardous electrical
installations and only under the guidance of a qualified
electrician.
Additional information on use
Observe the technical safety regulations for working on electrical
systems, especially: 1. Safely isolating from power supply,
2. Securing to prevent system being switched on again,
3. Checking zero potential, two-pole, 4. Earthing and short-
circuiting, 5. Securing and covering adjacent live components.
Safety instructions
Using artificial, optical emission (OStrV)
LED outlet (see Fig. A)
• The device works with LEDs of risk group RG 0
(exempt, no risk) in accordance with the latest versions
of applicable standards relating to photobiological safety
(EN 62471:2008-09ff / IEC/TR 62471:2006-07ff).
• When used for the intended purpose and under reasonably
foreseeable conditions, the accessible radiation of the LEDs
is safe for the human eye and skin.
• Temporary, irritating optical effects (e.g. dazzling, flash
blindness, afterimages, colour vision impairment) cannot
be completely ruled out, especially under low ambient light
conditions.
• Do not intentionally look directly into the radiation source
for longer periods of time.
• No specific measures are required to ensure the limit values
of risk group RG 0 are maintained.