Setting The Timer; Convenience Operation; Care And Maintenance; Cleaning The Air Filter - Panasonic CS-V12CTP Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 65
5
3
2
1
4

SETTING THE TIMER

• Press the Timer Selection Button 1.
• Timer indicator on the indoor unit will light up.
• Select one of the following five types of operation.
Each time the button is pressed, the operation mode
is shifted in the arrow direction.
Delay OFF Timer
H
OFF
Delay ON Timer
H
ON
Delay OFF and
ON Timer
H
H
OFF
ON
Delay ON and
OFF Timer
H
H
ON
OFF
• Then press the Timer Setting Button 2 or 3 to the
desired number of hours.
(Number of hours which can be set : 1 ~ 12)
• Press the Timer Set/Cancel Button 4.
7
12CTP5-01EN(01-09)
7

CONVENIENCE OPERATION

■ Sleep Mode Operation
To obtain a comfortable room temperature while sleeping:-
• Press 5.
• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
● Sleep Mode Operation Details
• When the room temperature reaches the set temperature,
the airflow volume will change to low automatically.
• Sleep Mode Operation time is 8 hours.
• When used together with the timer, the timer has a priority.
Temperature
S
T
e
e
m
Example :
t
p
t
Sleep
Operation Stops
e
i
Operation
after 1 hour
r
button is
n
a
ON Timer.
pressed.
g
t
u
r
0~1 hour
e
Example :
Operation starts after
6 hours.
Temperature
Example :
S
T
Operation stops after
e
e
1 hour and re-starts
m
t
p
after another 5 hours.
t
e
i
r
n
a
g
t
u
Example :
r
Sleep
e
Operation starts after
Operation
10 hours, and then
button is
stops after another 8
pressed.
hours.
0~1 hour
Cooling Model
Approx. 0.5°C
increase.
Approx.
0.5°C
increase.
• Cooling or Soft Dry
Operation for sleep shift
operation will start to
Sleep shift
avoid overcooling.
operation
starts.
← 1 hour →
Time
after approx. 8 hours of sleep shift
operation, it will stop automatically.
Heat Pump Model
Approx. 0.5°C
increase.
Approx.
0.5°C
• Cooling or Soft Dry
increase.
Operation for sleep shift
operation will start to
avoid overcooling.
Sleep shift
operation starts.
• Heating operation for
sleep shift operation will
start to avoid overheating.
Approx. 2°C
decrease.
← 1 hour →
Approx. 3°C
decrease.
← 1 hour →
Time
after approx. 8 hours of sleep shift
operation, it will stop automatically.
12/24/09, 11:29 AM

CARE AND MAINTENANCE

■ Cleaning the Indoor Unit and Remote
Control
• Wipe gently with a soft, dry cloth.
• Do not use water hotter than 40˚C or polishing fluid
to clean the unit.

■ Cleaning the Air Filter

(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency)
1
Remove dirt using a vacuum cleaner.
2
Wash back of the air filter with water.
3
If badly soiled, wash it with soap or a mild household
detergent.
4
Let it dry and reinstall it.
Be sure the "FRONT" mark is facing you.
* Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD001088.
• Do not use benzene, thinner, scouring powder or
clothes soaked in caustic chemical to clean the
unit.