Introduction
Power Management Signalling (DPMS) method, which is endorsed by
the EPA, is the power-down process a system should use to
communicate to the monitor to save power. Power-down functions can
be utilised only with an Energy Star system or video card which adheres
to the VESA DPMS standard. By using the monitor's horizontal and
vertical SYNC signals, the monitor can be prompted into the different
IPM modes. The following is the description of the LED indicator for
the IPM power-saving modes:
Mode
On
Stand By
Suspend
Off (IPM Mode)
Off (Power
Switch, Off)
Reduced Emissions
The A
/A
monitor incorporates Reduced Magnetic Field technology
500
700
designed to reduce magnetic and alternating electric field emissions and static
electricity. NEC's monitors follow the strictest magnetic field, alternating
electric field, and electrostatic recommendations of the Swedish Board for
Technical Accreditation, or SWEDAC (previously known as MPR, National
Board for Measurement and Testing). The JC-1736VMB-1/JC-1736VMR
follow the recommendations of the TCO which specify maximum
recommended values of electric and magnetic field.
LED Indicator
Green
Green
Yellow
Orange
No Light
Power Saving
None
Minimum (Quickest Recovery)
Moderate (< 15 Watts, Moderate
Recovery)
Maximum (< 8 Watts (A
< 5 Watts (A
), Slow Recovery)
700
No Power Used (Fully Off)
E - 3
)/