STEP 2C
CAUTION:
Avoid potential personal injury
or property damage!
● Studs must be at least 2x4 / 25 ga.
● If back side of wall is unfinished, drywall must be
installed to a minimum of one stud left and right
of the stud(s) being used to install the mount
● Drywall must be a minimum of 1/2 in. (13
mm) thick on each side of the studs, and a
minimum clearance of 1 ⅞ in. (48 mm)
behind the wall is required
● This product must be centered on the studs
● Stud type and structural strength must conform to
the North American Specification for the Design of
Cold-Formed Steel Structural Members
[362 S 125 18, C-Shape, S - Stud Section]
● Drywall must be secured to studs with screws
12 in. (304.8 mm) on center
4
POSITION TEMPLATE
06
To calculate your precise wall plate location, check out
TIP:
our Height Finder at sanus.com [www.san.us/1172].
6
INSTALL ANCHORS
a
S1
c
P
S1
CAUTION:
Be sure cap
seated against the drywall surface.
8
Steel Stud Installation
1
Visit
HeightFinder™
www.
san.us/1172
b
S1
d
S1
is
P
Min. 16 in. (40.6 cm)
LOCATE
5
DRILL
4X
CAUTION:
7
SECURELY TIGHTEN
07
CAUTION:
All four screws
unwanted movement of the wall plate
securely fastened to the wall before continuing on to the next step.
Steel Stud Installation Kit SSMK1 (NOT INCLUDED)
S2
x4
S1
1/4-20 x 1 ¾ in.
1/4-20 SNAP Toggle BB
*
Contact Customer Service to inquire about the additional hardware.
2
VERIFY
06
Be sure you drill into the CENTER of the stud.
4X
S2
Avoid potential personal injury or property damage!
MUST BE firmly tightened to prevent
S2
07
*
x4
x4
S3
1/4 in.
3
MARK
1 in. (25 mm)
1/2 in.
(13 mm)
S3
. Ensure the wall plate is