Simu T5 Hz.0 Manual De Instrucciones página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
8.2- Re-adjustement of DOWN end limits:
1- Position the motor on the DOWN end limit previously
set in §4.3a with the DOWN key.
2- Press simultaneously for 5 secondes the UP and DOWN
keys, The motor will run for 0,5 second in one direction
and then in the other direction.
3- Adjust the new position with the UP and DOWN keys.
4- Validate the new position by pressing 2 seconds the
STOP key. The motor will run for 0,5 second in one
direction and then in the other direction. The new end
limits setting is memorized.
9
Cancelling programming and settings
9.1
1- Switch off the power supply to the receiver for 2 seconds.
2- Switch the power to the receiver back on for 7 seconds.
3- Switch off the power supply to the receiver for 2 seconds.
3- Switch the power to the receiver back on.
- If the motor is on the end limit position (up or down), the motor
will run briefly on one direction and then in the other, otherwise,
the motor runs for 5 seconds in random direction.
The motor is now in the "cancelling" mode.
If you switch off the power to several motors, they will all be in cancelling mode. That is why, you must
"eject" out of this mode all the receivers that are not to be deprogrammed by sending a command from their
individual control transmitter (UP or Down).
9.2- Then, validate the cancelling of the affected motor from the individual control:
- Press the "PROG" key of the transmitter more than 7 seconds.
Maintain the pressure until the motor will first run for 0,5 second
in one direction and then the other, and a few second later, it will
run again in both direction.
The Hz.02 motor is now as it was originally configured, and
no transmitter and no settings is saved in its memory and is
ready for a new programming.
Hereby, SIMU, declares that this equipment "T5Hz.02 / T6Hz.02" is in compliance with the essential requirements and other relevant provision of Directive
1999/5/EC. A declaration of Conformity is available at the web address: www.simu.fr, heading "Normes". Usable in EU, CH
4/4
1
2
5s
OFF
ON
8.1
2s
8.2
7s
8.3
>>
PROG 7s
3
4
2s
OFF
ON
2s
8.4
>>
2s
7s
5s

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T6 hz.02T5 hz.02

Tabla de contenido