Multi_ING_Man_GenioPUNTOE_03
2.3 TROUBLESHOOTING
Please remember that any necessary repairs must be carried out carefully following the indications given
by the manufacturer and using only original spare parts or parts which have been approved by the
manufacturer and maintain the production characteristics of the Radio Remote Control unaltered.
Before calling the help centre, please verify where and how the malfunction occurred.
When operation inconveniences occur, first make sure that the fault is caused by the Radio Remote Control System
by replacing the Radio Remote Control with the traditional Cable Control. If the machine works correctly with the
Cable Control, the problem is caused by the Radio Remote Control. In this case it is therefore necessary to
reconnect the Radio Remote Control and verify if the malfunction is among those listed in the table below.
PROBLEM
After having switched on
the device and pressed
the
start
button
the
external
control
LED,
positioned
on
the
transmitting unit, does not
light
up
or
lights
steadily and the Buzzer
sounds.
The external control LED,
located on the transmitting
unit,
blinks
but
the
machine does not start.
If other types of problems occur, please request the intervention of AUTHORISED PERSONNEL.
If parts of the transmitting or receiving unit have to be replaced, please remember to remove the battery
•
from the transmitting unit and disconnect the receiving unit from the electric panel of the machine.
The following is essential if the radio modules are to be replaced: make sure that the module pre-setting
•
micro-switches (the replaced one and the replacement) are the same; remove the connection key from
the module being replaced and apply it to the replacement module.
CHECKS
- Make sure that all the command actuators are at OFF and in particular that the
mushroom button has not been activated;
- Insert a battery which you are certain is charged;
- Make sure that the contacts of the transmitting unit battery and/or the battery
charger have not oxidised or are not damaged.
up
- Make sure that the receiving unit POWER light is lit. If it is not, check if the fuses
inside the receiving unit are integral and also check power connection;
- Make sure that when the transmitting unit is started the RF SIGNAL and RC
CONNECTION lights on the receiving unit light up. These lights indicate that a radio
link has been established between the transmitting and the receiving units. If the
lights do not light up, even if the units are close to each other, call the technical help
service.
- If the lights on the receiving unit are all lit, check the condition of the internal fuses.
- Page 5 -
GENIO-PUNTO.E Radio remote control system