INTRODUCTION
Technical Features:
Cover Options: Steel - White Epoxy.
Surface Mounted.
Sensor Operated - Adjustable Detection Range: 2-6 inches (5-15 cm).
Voltage: 110 - 120 Volt at 50/60 Hz and 220-240 Volt at 50/60 Hz with - CE option.
NOTE: For dryer to function properly, a minimum of 16 inches (41 cm) should be spaced between
the hand dryer sensor and any obstruction such as shelves, hand washing stations, or any type
of reflective surface.
MACHINE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED TECHNICIAN
INSTALLATION
1. Dismantling for installation
Note: Sensored model has a proximity sensor
mounted to the cover near the air outlet.
Unscrew lock screws with security wrench
provided (P/N: P15-441).
Remove cover vertically, taking care to avoid:
- Damaging internal components.
- Damaging cover (See Figure 1).
2. Mounting
Use template provided for referencing drill locations.
Drill four holes with diameter appropriate for fasteners being used (not provided).
Remove all dust.
Loosely attach mounting plate to wall (See Figure 2).
Pull wiring through knock-out location (See Figure 3).
Tighten mounting plate to wall.
Connect electrical wiring to terminal strip.
Secure cover to unit by tightening screws using security wrench provided (P/N: P15-441).
For sensored models, place hands inside detection area and activate unit to ensure the hand dryer
is working properly.
Figure 2
1
CAUTION: do not damage the IR sensors in automatic models
Figure 1
N
L
GR
Knock-out location
Figure 3
www.bradleycorp.com