Engel MD14F El Manual Del Propietario página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
5 Defrosting
Due to the humidity within the cabinet, frost will form on the evaporator surface when
it has been running for sometime. A layer of frost in excess of about 6mm(1/4in), has on
adverse effect upon cooling efficiency, therefore the evaporator must be defrosted at
regular intervals. For this purpose, you may stop the fridge by pulling the cigarette lighter
plug from the socket.
6 CAUTION AND HOW TO REPLACE THE SPECIAL THERMAL FUSE
This refrigerator has the DC cord plug incorporating the special thermal fuse, which cut
off current at an abnormal situation like abnormally over-heated plug.
WARNING
・Do not use a glass tube fuse selling at a shop on market.
・This special thermal fuse has a polarity, and when replacing, please read how to replace
the special thermal fuse as below-mentioned, and replace it after you check the
polarity connection is correct.
HOW TO REPLACE (Fig 7)
1 . Take off the cover at the nose of the DC cord plug by tur ning the cover
counterclockwise.
2 . When taking off the cover, the head terminal and the special thermal fuse are also
taken off at the some time.
3.Pull out the special thermal fuse from the head terminal.
4.When the special thermal fuse is blown, replace with a new one after your check
whether the polarity connection is correct.
CAUTION
・Use the special thermal fuse of SAWAFUJI made without fail.
・The special thermal fuse should be placed in the plug in such that the direction of the
arrow indicated on the special thermal fuse looks forward the head terminal. (Fig 7)
5.Assemble the DC cord plug following with the reverse order of disassembly and tighten
the cover firmly.
− 7 −

Publicidad

Tabla de contenido
loading

Tabla de contenido