Care and Cleaning

Remove cartridge and clean valve body in household vinegar to remove corrosive mineral build up. Rinse
under running hot water to ensure valve is free of foreign debris.
Trouble Shooting Chart
Problem
Water flow is less than normal.
Water continues to run colder than
original temperature setting.
Valve is leaking around the cap
retaining nut area.
Tempered hot water temperature is
not hot enough.
Symmons Industries, Inc.
6
©2013 Symmons Industries, Inc.
Cause
Screen in valve is dirty or cartridge
is dirty or clogged.
Check valve is not completely
sealed allowing cold water to mix
with hot.
Water leaking from o-ring seal.
Hot water supply into valve is not
10°F (5.55°C) above desired set
point temperature.
31 Brooks Drive
Braintree, MA 02184
www.symmons.com
gethelp@symmons.com
Solution
1) Remove screen and clean under
running water.
2) Remove cartridge and clean in
household vinegar or replace by
ordering cartridge replacement kit.
Remove screen/check valve and
clean under running water.
Replace o-ring by ordering
cartridge replacement kit.
Increase hot water supply
temperature into valve.
(800)796-6667
Fax: (800)961-9621
ZV-3010 REV D 05/27/14