4. INDOOR UNIT INSTALLATION

4-1
INDOOR UNIT MOUNTING BRACKET INSTALLATION
• Install the bracket firmly to the wall structure (stud, etc.).
• Use a level to install the mounting bracket horizontally.
• Install the indoor unit 150 mm or below from the floor.
Indoor unit mounting bracket 7
4-2
INDOOR UNIT PREPARATION
• Press the 2 positions indicated by the arrows e and open the front grille.
• Open the front grille and remove the two screws.
• Open the horizontal vane for the upper air outlet, push the top of the front panel in three locations, and then
pull the top of the grille away from the indoor unit.
• Lift up the front grille to remove it.
Screws
To prevent the indoor unit mounting bracket 7 from vi-
brating slightly, be sure to fasten the bracket at the holes
indicated by b. In addition, fasten the bracket at the holes
indicated by f if possible.
4
4-3
INDOOR UNIT INSTALLATION
• Hook the top of the indoor unit on the indoor unit mounting bracket 7.
• Use the included wood screws 9 and washer 0, and fasten the indoor unit at 2 locations(e) each at the top
and the middle of the unit.
4-4
CONNECTING WIRE SPECIFICATIONS
• Use special room air conditioning circuit.
Indoor/outdoor unit connecting
Cable 4-core 1.5 mm
wire Specification
with Design 245 IEC 57.
Warning:
Never cut the indoor and outdoor unit connecting wire and connect it to other wires. It may cause a fire.
674