Some tips for measuring capacitance:
• The meter may take a few seconds (>30 seconds in 600.0µF range) to stabilize reading. This is
normal for high capacitance measuring.
• To improve the accuracy of measurements less than 6nF, subtract the residual capacitance of the
Meter and leads.
• Below 100pF, the accuracy of measurements is unspecified.
Figure 3-3

Measuring Capacitance

3.2.4 Continuity Check

To avoid electrical shock and/or damage to the instrument, disconnect circuit
power and discharge all high-voltage capacitors before testing for Continuity.
To test for continuity (set up the Meter as shown in Figure 3-4):
1. Set the rotary switch to
2. Connect the black and red test leads to the COM and Ω terminals respectively.
3. Connect the test leads to the resistance in the circuit being measured.
4. When the test lead to the circuit is below 50Ω, a continuous beeping will indicate it.
NOTE: Continuity test is available
to check open/short of the circuit.
range.
11