GB
REARMING INSTRUCTIONS
Locking ring
Cap
5.
6.
Green indicator
Caution!
Do not turn
Single
center shaft
point
indicator
7b.
8.
Black locking ring
1
2b.
Key
Red indicator
Inflator
body
Sealing ring
7a.
Water
Inlet
valve
9b.
9a.
Single point
indicator
Pull to
inflate
lanyard
Locking ring
Making the inflator operational after use
1. Place the lifejacket (PFD) on a smooth,
flat surface and wipe off any water.
Hold the gas cylinder through the fa-
bric, using one hand. (PFD = Personal
Floating Device)
2. Insert metal key as shown in 2a and
turn the key counter-clockwise (2b)
between black locking ring and label-
led yellow cap. The black locking ring
will now turn counter-clockwise.
3. Now turn black locking ring counter-
clockwise (3a) and lift off cap (3b).
(cap = yellow inflator operating head).
Dispose of used cap.
4. Squeeze sealing ring to elongate and
remove the inflator body through the
sealing ring.
Dispose of used inflator body in an
environmentally approved manner.
5. Check that the indicator is green.
Insert new inflator body with gas
cylinder pointing upwards inside the
lifejacket (PFD). Let the sealing ring
rest on the inflator body around the
four lugs.
6. Now check the new manual/automatic
cap as follows:
1. Single point indicator showing
green?
2. Expiry date OK?
If YES is the answer to both these
questions, then proceed as follows.
If NO, get a new cap.
7. Hold the gas cylinder through the
fabric of the lifejacket (7a). Position
the replacement cap with the water
inlet valve pointing to the right (7b) and
press it FIRMLY onto the inflator body
and sealing ring.
8. While pressing FIRMLY onto the
inflator body turn the black locking
ring clockwise into the locked position.
Pull on the cap to make sure it has
locked onto the inflator body.
9. CHECK:
To see that the indicator on the cap is
green; that the pull to inflate lanyard
is present and that the locking ring is
locked. (9a) When the locking ring is
locked, it cannot be turned counter-
clockwise by hand. If your lifejacket
(PFD) has been used and/or the
Hammar Inflator replaced, always
inflate the jacket through the oral
tube (9b) and check that it stays
inflated at least overnight. Empty the
lifejacket (PFD) again by pushing in the
non-return valve in the top of the oral
tube and press out ALL RESIDUAL
AIR from the bladder, so that the
jacket may be folded properly. Let the
lifejacket dry before packing.
Don't forget the annual service on
your lifejacket!
For further information on periodical
checking and annual service, you are
always welcome to visit our web-site:
www.cmhammar.com.
MA1