AXIS Q6055-C PTZ Dome Network Camera
Maintenance
How to clean the outer heat sink
Dust and particle buildup could affect the performance of the cooling system. To maintain the
performance level, the outer heat sink in the camera's cooling system may need occasional or
regular cleaning.
CAUTION
The heat sink could be hot. Be careful when touching the heat sink and the heat sink cover.
If required, let the camera cool before touching it.
1. Disconnect the multicable.
2. Loosen the screws and remove the sunshield.
1
Screw T20 (3x)
2
Sunshield
3. Remove the screws (Torx T30) and lift the heat sink cover.
NO
NO TICE
NO
TICE
TICE
Do not strain the fan cables or let the heat sink cover hang by the fan cables.
21