Installing the Lamp Inserts
The light effect unit is supplied without lamp inserts.
Important! Prior to installing resp. replacing the lamps disconnect the mains plug in
any case! As halogen lamps become very hot during operation, at first let the lamps
cool down after operation of the unit (cooling down time at least 5 minutes) before
replacing them.
Two halogen lamps of 230V/300w, socket GY 6,35 or Gx 6,35 are required.
1) Screw off the screws of the lamp compartment and open it:
2) When replacing the lamps, carefully draw the two old lamps out of the holders.
3) To avoid impurities of the new lamps by skin grease, they should not be touched with the fingers
but with a soft cloth. Insert the new halogen lamps; place the pin sockets of the lamps into the
lamp holders.
4) Tightly close the lamp compartment again with the screws.
Mounting
1) Fix the unit via the mounting bracket with a support for light radiating units or a stable moun-
ting screw at the desired place (traverse of a stand for light radiating units or horizontal bar).
2) For aligning the unit loosen the setscrews at the mounting bracket, adjust the desired inclination
of the unit, and tighten the setscrews again.
Important! To avoid a heat accumulation in the unit the mounting place must be chosen so that
sufficient air circulation is secured during operation. The vents of the housing must not be covered.
Operation
1)Connect the light effect unit with the mains plug to a mains socket (230V_/50Hz). With connecti-
on to the power supply the unit is switched on.
2) Adjust the desired volume at the music system.
3) Adjust the desired microphone sensitivity with the rotary control. If the control is turned coun-
terclockwise up to the stop, the microphone is switched off. The further the control is turned up
clockwise, the higher the microphone sensitivity becomes. Adjust the control so that the volume of
sound of the music is reproduced by the rotating light beams is an optimum way.
NOTE:
When changing the volume at the music system, the microphone sensitivity must also be matched
accordingly by the rotary control.
4) For switching off the unit disconnect the mains plug.
Specifications
Model
Power Supply
USB 9005
230V~/50Hz/620VA
USB 9004
230V~/50Hz/620VA
USB 9008
230V~/50Hz/620VA
USB 9009
230V~/50Hz/620VA
USB 9007
230V~/50Hz/620VA
© US Blaster Europe BV
Lamps Inserts
2 halogen lamps (230V/300W
socket GX 6,35 or GY 6,35)
2 halogen lamps (230V/300W
socket GX 6,35 or GY 6,35)
2 halogen lamps (230V/300W
socket GX 6,35 or GY 6,35)
2 halogen lamps (230V/300W
socket GX 6,35 or GY 6,35)
2 halogen lamps (230V/300W
socket GX 6,35 or GY 6,35)
Dimensions
(w/o mounting bracket)
34x30x28cm (WxHxD)
31x37.8cm (øxD)
46.5x39x20cm(WxHxD)
46.5x39x20cm(WxHxD)
46.5x39x20cm(WxHxD)
Weight
3.4kgs
3.2kgs
7.4kgs
8.6kgs