Eikon
Arké
20162
19162
20162 - 19162 - 16602 - 14162
230 V~ 50 Hz dimmer for
40-300 VA electronic capacity transformers, control-
C
led and adjusted with incorporated buttons or from several points with NO buttons,
MOSFET technology, visible in the dark.
Characteristics
• Lighting, adjusting and turning off with incorporated buttons or normal buttons
without pilot light when off.
• Lighting level is saved when turned off (unless there is a blackout).
• Soft start: ensures gradual lighting from zero to maximum or preset lighting levels.
This way the life of a lamp is increased by reducing stress on the filament and
prevents light flash.
• Soft end: ensures a gradual passage from light to dark.
• Protection against short-circuit when turning on together with flashing blowout
detector.
• Overheating protection with flashing blowout detector.
• It should be used in dry, dust-free places at a temperature between 0 °C and +35 °C.
Connections
The connection should be made together with a fuse box with quick-acting fuse with
high breaking capacity type F2,AH 250 V~ (07050.HF.2) as seen in the diagrams
below.
• control and dimming with incorporated button or several points with NO buttons in
parallel (figure A). Do not use NO buttons with pilot light.
Controllable loads
• Dedicated VIMAR electronic transformers 01860.60 max 5, or VIMAR 01860.105
max 3.
Controllable
Characteristics of
loads
controllable transformer
Constructor further information
• Electronic capacity transformers
ers).
• Not suitable for controlling motors (e.g. fans, ventilators).
• For installations with 2 dimmers in the same box the loads controllable by each
dimmer should be reduced so that their total does not exceed the values indicated
above.
Operating
• Turn on and off by pressing the button quickly and make adjustments by keeping it
pressed. Stop and restart to change direction.
When maximum or minimum load is reached, dimming stops and can be inverted
by pressing the dimmer again.
• If the pilot light does not turn on check the fuse and if necessary replace it with the
same model.
• If the pilot light flashes when turned on check it and replace the load if necessary
(short-circuit load).
• If the pilot light flashes after turning on, the load is in short-circuit or the installa-
tion has not been carried out correctly and the overheating protection has been
activated. Check and if necessary replace the load. If the problem remains have the
system checked by an expert.
Viale Vicenza, 14 - I 36063 Marostica VI
Tel. +39 0424 488 600 - Fax (Export) +39 0424 488 709
www.vimar.eu
Idea
Plana
16602
14162
20162
19162
16602
14162
40 - 300 VA
C
: 40-300 VA 230 V~ 50 Hz (max 5 transform-
C
Installation regulations
• The installation should be carried out in compliance with current electrical installa-
tion regulations in the country where installed.
• The rated power should never be exceeded.
• Overloading, power surges and short-circuits may permanently damage dim-
mers. Before installation check the circuit carefully and eliminate any of the above
causes.
• Do not connect several dimmers in series between each other.
• The dimmer does not have a mechanical circuit breaker in the main circuit and
so is not galvanically separated. The circuit load should be considered always
under voltage.
Standard compliance
BT directive
EMC directive
EN 60669-2-1 standard
L
N
20416
20162
19416
19162
16460
16602
14416
14162
ENGLISH

Instruction sheet

Publicidad

loading

Este manual también es adecuado para:

Arké 19162Idea 16602Plana 14162Idea 16602.b