INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
For best performance, mount the fi xture about 8 ft.
(2.4 m) above the ground.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fi xture to cool before touching. The bulb and
the fi xture operate at high temperatures.
• Keep fi xture at least 1" (2.5 cm) from combustible ma-
terials. Do not aim at objects closer than 3 ft. (1 m).
• Use only T3, 250W (max.) tungsten halogen 120
VAC lamps.
❒ Note the position of the various parts of the fi xture for
the type of installation for your application and adjust
the lamp head and sensor as shown below.
Wall Mount
Lens Retainer
Light Shield,
with opening at
For under eave installation, the sensor head must be
rotated as shown in the next two steps for proper operation
and to avoid the risk of electrical shock. Also for proper
under eave operation, remove the protective backing
from the Light Shield and stick on as shown below.
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so
the controls face down.
Light Shield
Opening
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
Eave Mount
this side
Lens Retainer
Controls
Controls
Controls
B
ULB
❒ When relamping, turn power off and let the fi xture
cool.
❒ Remove glass cover and remove the old bulb by
pushing the bulb towards the socket indicated on
the metal refl ector.
❒ To insert the new bulb, follow the instructions printed
on the metal refl ector.
❒ Check that the bulb is seated properly.
❒ Reinstall the glass cover.
W
IRE THE
WARNING: Turn power off at circuit breaker
or fuse.
❒ Remove the existing light fi xture.
❒ Install mounting strap to junction box using screws
appropriate for your junction box.
❒ The plastic hanger can be used to hold the fi xture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
❒ Thread all fi xture wires through the large holes in
the gasket as shown.
❒ Connect the junction box wires to the light fi xture
wires as shown. Twist together and secure with wire
connectors.
Mounting Strap
Black to Black
Connect any fi xture ground wire(s) and the cover plate
ground screw to the junction box ground wire.
M
OUNT THE
❒ Align the Light Control cover plate and cover plate
gasket. Secure with the mounting bolt.
❒ Push the Rubber Plug fi rmly into place.
❒ If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone weather
sealant.
2
I
NSTALLATION
L
C
IGHT
ONTROL
White to White
Mounting
Gasket
L
C
IGHT
ONTROL
598-1311-00
Rubber
Plug
Bolt