12 pg_W-024_EFS
11/8/04
MOUNTING AND WIRING INSTRUCTIONS
CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal
between the fixture and the mounting surface by using silicone or similar caulking.
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These
fixtures meet all UL specifications.
1. Turn off power at circuit box to avoid possible electric shock.
2. Remove cap nuts (A) from back plate (B) and remove universal mounting plate or cross bar
(C), leaving mounting screws (D) in place (see fig. 1).
3. Secure universal mounting plate or cross bar (C) (horizontally or vertically, see fig. 1) to
outlet box (E) with outlet box screws (F) (not included).
4. Identify color coding of fixture wires (see fig. 2).
5. To connect wires, take black fixture wire (group A from fig. 2) and place evenly against
black outlet box wire. Do not twist wires.
6. Fit wire connector (G from fig. 1) over wires and twist until there is a firm connection. If
wire connector (G) easily comes off, reattach and check again for a firm connection.
7. Repeat steps 5 and 6 with the white (group B from fig. 2) fixture and outlet box wires.
8. Partially thread green grounding screw (H) into side hole (I) on universal mounting plate or
cross bar (C) (see fig.1).
9. Wrap ground wire from fixture around green grounding screw (H) leaving enough excess
wire to then connect ground wire and outlet box wire with wire connector (G), if applicable.
10. Tighten green grounding screw (H). Do not over tighten.
11. Tuck wires inside outlet box (E) (see fig. 1).
FIXTURE ASSEMBLY INSTRUCTIONS
1. Place back plate (B) over mounting screws (D) (see fig. 1).
2. Secure into place with cap nuts (A).
3. To remove glass shade (J), carefully support bottom of glass shade (J) while removing
thumbs screws (K) from fixture cover (L) (a Phillips screwdriver is needed).
4. Carefully lower glass shade (J).
5. Install lamp(s). Do not exceed recommended wattage.
6. Replace glass shade (J), and thumb screws (K).
7. Turn power back on at circuit box.
12:17 PM
Page 4
4