Descargar Imprimir esta página

Xpelair Premier CF20 Manual Del Usuario página 5

Publicidad

N
S
Tilbehør
Tillbehör
For å forenkle installasjonen og
I listan nedan hittar du hjälpmedel
spare tid, kan det være at din
som kan vara av nytta under
installasjon krever noe av
installationen:
tilbehøret som er listet opp
nedenfor:
WD100
Väggtrumma
CFWG100 Väggaller
WD100
Vegg-gjennomføring
FDA
Adaptorsats för
CFWG100 Vegg-gitter
planmontering
FDA
Utstyrspakke med
XCT100
Kondensavledare
plant kanaladapter
DGW/B
Luftregleringsgaller
XCT100
Kondensavskiller
SP100
Mufförbindningsplatta
DGW/B
Gitterluke for
luftutskiftning
XAA
Adapter
SP100
Muffeplate
VC10
Ventilhuv
XAA
Luftadapter for mur
WT10
Avspänningssats
VC10
Avtrekksdeksel
XF/FM
Planmontering
WT10
Kanalavslutnings-sett
(plast/metall)
XF/FM
Plan rørkanal
(plast 234 x 29 mm)
(plast/metall)
(metall 230 x 25 mm)
(plast 234 x 29 mm
VK10
Väggventilsats
metall 230 x 25 mm)
FD100
Flexibel
VK10
Veggventil-sett
ledningsdragning
FD100
Fleksibel rørkanal
WDC5
Skruvdriftsklämmor
WDC5
Snekkeskrue-klips
XCMK
Takmonteringssats
XCMK
Sett for montering i
XBP
Svart reglerventil
himling
EFT
Avspänningssats
XBP
In-line
GMK
Glasmonteringssats
tilbakeslippsklaff
EFT
Lettmontert
PDXGF
Smörjningsfilter
avslutnings-sett
I listan nedan hittar du
GMK
Sett for montering i
reservdelar. Du hittar
vindu
beställningsinformation på denna
PDXGF
Fettfilter
bruksanvisnings baksida:
Nedenfor er det listet opp enkelte
41520SK Fastsättningssats
reservedeler som er tilgjengelige.
(komplett)
Se baksiden på denne trykksaken
41528SK Mufförbindning
for bestillingsinformasjon:
(komplett sortiment)
41731SK Motor (DX200)
41520SK Monterings-sett
41733SK Motor (CF20/CF20T/
(komplett)
DX200T)
41528SK Rund muffe (komplett)
41782SK PCB-montering
41731SK Motor (DX200)
(DX200T)
41733SK Motor (CF20/CF20T/
41735SK PCB-montering
DX200T)
(CF20)
41782SK Kretskort-komponent
41736SK PCB-montering
(DX200T)
(CF20T)
41735SK Kretskort-komponent
41737SK Främre skydd med
(CF20)
skärm (DX200)
41736SK Kretskort-komponent
41738SK Främre skydd med
(CF20T)
skärm (DX200T)
41737SK Frontdeksel kompl.
41739SK Främre skydd med
med mottrykksplate
skärm (CF20/CF20T)
(DX200)
41740SK Ramformning
41738SK Frontdeksel kompl. med
(komplett sortiment)
mottrykksplate (DX200T)
41741SK Dragsnöresmontering
41739SK Frontdeksel kompl. med
(CF20/CF20T)
mottrykksplate
41742SK Fläkthjul (komplett
(CF20/CF20T)
sortiment)
41740SK Innfatningsprofil
(komplett)
41741SK Snorbryter-komponent
(CF20/CF20T)
41742SK Viftehjul (komplett)
I
GR
Συµπληρωµατικές Επιλογές
Accessori opzionali
Per un'installazione più facile e
Για γρήγορη και εύκολη
veloce, potrebbero essere
εγκατάσταση, η εγκατάσταση
necessari alcuni degli accessori
σας µπορεί να χρειαστεί µερικά
sottoelencati:
απ τα Συµπληρωµατικά που
αναφέρονται πιο κάτω:
WD100
Condotto per parete
WD100
Αγωγ ς τοίχου
CFWG100 Grata per parete
CFWG100 Κιγκλίδωµα τοίχου
FDA
Kit adattatore per
condotto piatto
FDA
Προσαρµογέας
XCT100
Pozzetto di
επίπεδου αγωγού
intercettazione della
XCT100
Ατµοπαγίδα
condensa
DGW/B
Κιγκλίδωµα π ρτας
DGW/B
Grata dello sportello di
ανανέωσης αέρα
ricambio aria
SP100
Πλάκα βύσµατος
SP100
Piastra di imbocco
XAA
Προσαρµογέας
XAA
Adattatore per mattoni
traforati
τούβλου αέρα
VC10
Cappottatura di
VC10
Κάλυµµα αεραγωγού
ventilazione
WT10
Σύνολο αγωγού
WT10
Kit di terminazione
τερµατισµού
condotti
XF/FM
Επίπεδος αγωγ ς
XF/FM
Condotti piatti
(πλαστικ /µέταλλο)
(plastica/metallo)
(plastica 234 x 29mm,
(Πλαστικ 234 χ 29 χλστ.
metallo 230 x 25mm)
Μέταλλο 230 χ 25 χλστ.)
VK10
Kit di ventilazione per
VK10
Σύνολο αεραγωγού
parete
τοίχου
FD100
Condotti flessibili
FD100
Εύκαµπτος αγωγ ς
WDC5
Fermagli a vite senza
WDC5
Κλιπ οφιοειδούς
fine
κίνησης
XCMK
Kit di montaggio al
soffitto
XCMK
Σύνολο τοποθέτησης
XBP
Otturatore in linea del
σε ταβάνι
tiraggio di ritorno
XBP
Φράχτης
EFT
Kit di terminazione di
οπισθοδροµικού
facile montaggio
ρεύµατος in-line
GMK
Kit per il montaggio su
EFT
Σύνολο
vetro
τερµατισµού
PDXGF
Filtro antigrasso
εύκολης εφαρµογής
Qui di seguito sono elencati alcuni
GMK
Σύνολο τοποθέτησης
dei ricambi disponibili. Per
γυαλιού
informazioni su come ordinarli,
PDXGF
Φίλτρο γράσου
consultare la quarta di copertina:
Πιο κάτω αναφέρονται µερικά
απ τα διαθέσιµα ανταλλακτικά.
41520SK Kit di fissaggio (kit
intero)
Συµβουλευθείτε την πίσω ψη
41528SK Imbocco a bicchiere
του παρ ντος φυλλαδίου για
circolare (intera
λεπτοµέρειες παραγγελίας:
gamma)
41520SK Σύνολο στερέωσης
41731SK Motorino (DX200)
(ολ κληρο σύνολο)
41733SK Motorino (CF20/
41528SK Κυκλικ βύσµα
CF20T/DX200T)
41731SK Μοτέρ (DX200)
41782SK Gruppo PCB
41733SK Μοτέρ (CF20/CF20T/
(DX200T)
DX200T)
41735SK Gruppo PCB (CF20)
41782SK Σύνολο PCB (DX200T)
41736SK Gruppo PCB (CF20T)
41735SK Σύνολο PCB (CF20)
41737SK Coperchio anteriore
41736SK Σύνολο PCB (CF20T)
completo di
diaframma (DX200)
41737SK Μπροστιν κάλυµµα
41738SK Coperchio anteriore
συνοδευ µενο απ
completo di
εκτροπέα (DX200)
diaframma (DX200T)
41738SK Μπροστιν
41739SK Coperchio anteriore
κάλυµµα
completo di
συνοδευ µενο απ
diaframma
εκτροπέα (DX200T)
(CF20/CF20T)
41739SK Μπροστιν κάλυµµα
41740SK Modanatura della
συνοδευ µενο απ
cornice
εκτροπέα (CF20/CF20T)
(intera gamma)
41740SK Χυτ πλαίσιο
41741SK Gruppo cordicella
(ολ κληρη σειρά)
(CF20/CF20T)
41741SK Σύνολο κορδονιού
41742SK Girante (intera
gamma)
τραβήγµατος
(CF20/CF20T)
41742SK Στροφείο
(ολ κληρη σειρά)
GB
IMPORTANT
1. READ ALL THESE INSTRUCTIONS & WARNINGS FULLY BEFORE COMMENCING INSTALLATION.
2. INSTALLATIONS AND WIRING MUST CONFORM TO CURRENT IEE REGULATIONS (UK), LOCAL OR APPROPRIATE
REGULATIONS (OTHER COUNTRIES). IT IS THE INSTALLER'S RESPONSIBILITY TO ENSURE THAT THE APPROPRIATE
BUILDING CODES OF PRACTICE ARE ADHERED TO.
3. A QUALIFIED ELECTRICIAN MUST SUPERVISE ALL INSTALLATIONS.
4. THESE APPLIANCES ARE INTENDED FOR CONNECTION TO FIXED WIRING
5. CHECK THAT THE ELECTRICAL RATING SHOWN ON THE FAN MATCHES THE MAINS SUPPLY.
6. WARNING: THESE APPLIANCES MUST BE EARTHED.
7. SITE AWAY FROM DIRECT SOURCES OF HEAT (I.E.: GAS COOKERS OR EYE-LEVEL GRILLS) AND NOT WHERE
AMBIENT TEMPERATURES ARE LIKELY TO EXCEED 50˚C.
8. WHEN THE FAN IS INSTALLED IN A ROOM CONTAINING A FUEL BURNING APPLIANCE, PRECAUTIONS MUST BE TAKEN TO
AVOID THE BACKFLOW OF GASES INTO THE ROOM FROM THE OPEN FLUE OF THE FUEL BURNING APPLIANCE.
9. ENSURE THAT ALL RELEVANT SAFETY PRECAUTIONS (CORRECT EYE PROTECTION AND PROTECTIVE CLOTHING
ETC) ARE TAKEN WHEN INSTALLING AND MAINTAINING THIS FAN.
10. GENERAL GUIDANCE FOR SITING THE FAN SEE "FIG. G". ALWAYS SITE FAN AS HIGH AS POSSIBLE
11. IF ANY SECTION OF THE DUCTWORK IS POSITIONED HIGHER THAN THE FAN A CONDENSATION TRAP (XCT100) MUST
BE FITTED AS CLOSE AS POSSIBLE TO THE FAN.
For speed and ease of Installation, your installation may require some of the
Ancillaries indicated in "Ancillary Options".
If installing on a wall (surface mounting)
Mark on the wall the centre of the duct hole A.
1.
2.
Use this centre to cut an opening through the wall 117mm dia, with a slight
fall to the exterior.
3.
Fit the wall duct (WD100), not supplied, and mortar into place.
If installing on a wall (flush mounting)
Mark on the wall the centre of the duct hole A, and drill a pilot
1.
hole through both walls at a slight downward angle.
2.
Use the centre to mark a rectangular hole for the inner wall using the
dimensions A.
3.
Cut the rectangular hole through the inner wall.
4.
Go outside and cut a 117mm-diameter hole in the outer wall using the small
hole as the centre.
5.
Measure the wall thickness.
Cut the wall duct (WD100), not supplied, so that it is 64mm less than the
wall thickness.
If installing in a ceiling (surface mounting)
This method requires a space above the ceiling, such as a loft or attic, to provide
access for 100mm internal diameter ducting.
Mark on the ceiling the centre of the duct hole A, avoiding ceiling joists and
1.
buried cables etc.
2.
Cut a 117mm-diameter hole using the marked centre.
If installing in a ceiling (flush mounting)
For 100mm diameter ducting:
Mark a rectangular hole using the dimensions B.
1.
2.
Cut the hole, avoiding ceiling joists and buried cables etc.
For flat ducting:
This fan can be installed within a 47mm void without the circular spigot 7
(Fig.E). Flat ducting adapter kit (FDA) available.
Preparing the fan for installation
1.
Remove the front cover 2 (Fig.C)
2.
Fit the foam tape !™ supplied around the circular spigot 7 (Fig.E).
3.
Remove the electrical cover 5 (Fig.E). The impeller can be removed to
ease access (if required). This is a "push-on/pull-off" assembly.
Setting the fan speed
DX200T / CF20 / CF20T Only (Fig.D)
4.
The correct condensation control speed (CF20/CF20T) or operating speed
(DX200T) should be selected to suit the room size in which the fan is to be
installed. Slide the switch X to the required position. Please note that the
fan is factory set to "Position 2".
5.
Switch Position
Size / Room Volume (m
3
)
1
Large (34 and above)
2
Medium (28 – 34)
3
Small (less than 28)
Setting the trickle speed
DX200T / CF20 / CF20T Only (Fig.D)
6.
The fan can be set so that it provides constant trickle extraction. Slide the
switch Y to the required position. Please note that the fan is factory set to
"Position 0".
7.
Switch Position
Setting
0
Trickle extraction OFF
I
Trickle extraction ON
Setting the time delay start
DX200T / CF20T Only (Fig.D)
8.
The fan can be set so that there is a 2-minute delayed start to its
operation when used with an external on/off switch. Slide the
switch Z to the required position. Please note that the fan is
factory set to "Position 0".
Switch Position
Setting
0
Time delay start OFF
I
Time delay start ON
Mounting the fan on a wall or ceiling (surface mounting)
1.
Place the ducting into the hole and align to the required position. If wall
mounting, ensure that the ducting slopes down and away from the fan
Mark the positions of the three fixing holes A in Fan box 6 (Fig.E).
2.
3.
If wall mounting, drill three holes 5.5mm diameter for wall plugs (supplied).
If ceiling mounting B , use appropriate fasteners (not supplied).
4.
Cut out the cable inlet hole, if required, in the surround 0 and slit the cable
grommet. Slide the surround 0 over the fan box 6.
Pass the electrical cables into the fan box 6 through the rear cable inlet
5.
hole and surround, and re-fit the cable grommet.
Ensure that cable grommet is in place and a tight fit.
Offer the fan box 6 up to the wall or ceiling. Ensure the circular spigot 7
6.
enters the ducting.
Fix the fan box 6 to the wall using screws 8 or to the ceiling using
7.
appropriate fasteners (not supplied).
If mounting in a wall (flush mounting)
The surround 0 is not required. Fit the ducting to the circular spigot 7.
If the hole size is as recommended:
Assemble the three fan body clamps 9 to the fan box 6 using screws 8.
1.
Slit the cable grommet. Pass the electrical cables into the fan box 6
2.
through the cable inlet hole and cable grommet.
Ensure cable grommet is in place and a tight fit.
Offer the fan box 6 up to the wall.
3.
Tighten up the three screws 8 until the fan is clamped to the inner wall.
4.
The fan body clamps 9 will rotate to an automatic stop position. DO NOT
OVERTIGHTEN.
If the hole size is larger than recommended i.e.: larger than the flange on the
fan box 6 6 (Mostly relating to "retro-fit" installations):
1.
The fan body clamps ARE NOT suitable. Construct a wooden frame of
INTERNAL dimensions 203 x 233mm. Depth should be at least 50mm. Fit the

Publicidad