ELECTRICAL CONNECTION
Warning - this appliance must be earthed
This appliance is designed for domestic use only. Connection to the mains supply must
be made by a competant electrician, ensuring that all current regulations concerning
such installations are observed.
The appliance must only be connected to a suitably rated spur point, a 3 pin 13 amp
plug/socket is not suitable. A double pole switch must be provided and the circuit must
have appropriate fuse protection. Further details of the power requirement of the in-
dividual product will be found in the users' instruction and on the appliance rating plate. In
the case of built-in product you are advised, should you wish to use a longer cable than
the one supplied, that a suitably rated heat resistant type must be used.
The wiring must be connected to the mains supply as follows:
CONNECT
TO SPUR TERMINAL
Green & Yellow
Wire Earth Connection
Blue Wire
Neutral Connection
Brown Wire
Live Connection
Note: We do not advocate the use of earth leakage devices with electric cooking applian-
ces installed to spur points because of the «nuisance tripping» which may occur. You are
again reminded that the appliance must be correctly earthed, the manufacturer decli-
nes any responsibility for any event occurring as a result of incorrect electrical installation.
Declaration of compliance: This equipment, in the parts intended to come into con-
tact with food, complies with the regulations laid down in EEC directives 89/109.
This appliance complies with directive 89/336/EEC, 73/23/EEC, 90/396/EEC and
the following changes.
GAS CONNECTION
The labels on the Hob indicate the types of gas that can be used.
It is possible to use other types of gas after carrying out simple modifications.
Warning: If gas can be smelt in the vicinity of this appliance turn off the gas supply to the
appliance and call the engineer directly. Do not search for a leak with a naked flame.
(FOR U.K. ONLY)
(FOR U.K. ONLY)
42
ELECTRICAL CONNECTION
Check the data on the rating plate, located on the outside of the unit, to ensure that the
supply and input voltage are suitable.
Before connection, check the earthing system.
By Law, this appliance must be earthed. If this regulation is not complied with, the
Manufacturer will not be responsible for any damage caused to persons or property.
If a plug is not already attached, fit a plug appropriate to the load indicated on the rating
plate. The earth wire is coloured yellow/green. The plug should always be accessible.
Where the Hob is connected direct to the electricity supply, a circuit breaker must be
fitted with at least a 3 mm contact spacing when in the open position.
If the power supply cord is damaged this is to be replaced by a qualified engineer so as
to prevent any potential risk.
The earth wire ( green a yellow coloured) must be at least 10 mm longer than the live
and neutral wires.
The section of the cable used must be of the correct size in relation to the absorbed
power of the hob.
Please check rating plate for the power details and ensure that the power supply cord
is of the type H05RR-F, H05VV-F, H05V2V2-F.
MAINS
SUPPLY
GAS CONNECTION
These instructions are for Fitters qualified for installation of equipment in line with the
relevant national standard. All work must be carried out with the electricity supply dis-
connected.
The rating plate on the hob shows the type of gas with which it is designed to be used.
It is possible to use other types of gas after carrying out some simple modifications.
(See the instructions in the following paragraphs).
connection to the mains gas supply or gas cylinder should be carried out according to
the relevant national standards, after having checked that it is regulated for the type of
gas with which it will be supplied. If it is not correctly regulated follow the instructions in
the paragraph entitlet «Adaption for different types of gas». For liquid gas (cylinder
gas) use pressure regulators which comply with the relevant national standards.
N.B.: for safe operation, economic use of energy and to ensure greater durability of the
appliance, make sure that the supply pressure conforms with the values shown in the
table on page 45.
Use only pipes, washers and sealing washers which comply with the relevant national
standards.
When connecting the hob to the gas supply via use of flexible hoses please ensure
that the maximum distance covered by the hose does not exceed 2 metres.
N.B.: carry out a final check for leaks on the pipework using a soapy solution.
Never use a flame. Also, make sure that the flexible pipe cannot come into con-
tact with a moving part of the cabinet (eg, a drawer) and that it is not situated
where it could be damaged.
GB IE
IE
GB
LIVE
L
BROWN WIRE
EARTH
GREEN/YELLOW WIRE
NEUTRAL N
BLUE WIRE
43
POWER
CABLE