Berner Multi HV-R Manual Del Usuario página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 25
OPERATION
Installing the appliance horizontally on a stable surface using tripod threaded connection
on a tripod at the desired height.
Switch 1 ON/OFF: Powers the laser up or down.
Power indicator: When the light is on, the instrument is on.
The unit starts automatically after the end of the leveling with the rotation.
If the unit is to be wrong (outside of the self-leveling), the laser and the rotation stops flas-
hing. The laser must be realigned.
Point operation
After turning the laser on and the automatic leveling is ready the unit is in the rotating ope-
ration. Press the button 2 and the rotation stops on the point.
In this mode, the highest visibility is achieved, since, in contrast to the moving beam, the
total laser energy is concentrated to one point.
In vertical mode, the laser spot can be used for easy alignment or parallel alignment.
Automatic Tilt off
By pressing the button 12 is the automatic tilt-off activated. In shock or change in position
the rotation stops, the laser flashes and automatically levels itself not a new.
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

245070245071

Tabla de contenido