Automatic filter cleaning
The appliance has an special filter cleaning
system that is particularly effective with fine
dust. The flat pleated filter is automatically
cleaned every 15 seconds (TACT MAX) or
every 60 seconds (TACT MIN) through an
air jet (pulsating sound).
Set the rotary switch to the desired pro-
gram (TACT MIN-TACT MAX).
Illustration
Power dedusting (especially with se-
vere soiling of the flat pleated filter): Set
the rotary switch to program 2, cover
the suction tube or the bender with your
hand and wait for the automatic filter
dedusting (every 15 seconds).
Turn off the appliance
Switch off the appliance at the rotating
knob.
Pull out the mains plug.
After each operation
Empty the container.
Vacuum and wipe the appliance inside
and outside with a damp cloth.
Storing the Appliance
Illustration
Store the suction hose (special acces-
sories) and mains cable as shown in the
illustration.
Place the appliance in a dry room and
secure it from unauthorized use.
Transport
CAUTION
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
Remove the suction pipe with floor noz-
zle or oven nozzle from the support.
Carry the device by the carrying handle
and the suction pipe, not by the push
handle.
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
14
CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.
Care and maintenance
DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Exchanging the flat pleated filter
Illustration
Open filter door.
Remove filter frame.
Replace the flat pleated filter.
During placement, make sure that the
flat fold filter rests against all sides.
Insert filter frame.
Close the filter door, it must lock into
place.
Cleaning the electrodes
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
Troubleshooting
DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Suction turbine does not run
Check the receptacle and the fuse of
the power supply.
Check the power cable, the power plug
and electrodes of the device.
Turn on the appliance.
Suction turbine turns off
Empty the container.
– 3
EN
Storage