Nr
Message
18
Next
maintenance
19
TP motor
20
Voltage sensor
21
No date/time
22
Flash error
23
Flash error
24
Flash error
25
Gas sensor
defective
26
Gas sensor,
undervoltage
27
Gas sensor,
overvoltage
28
Recurring
indication of
gas value "0"
26
Description
Reset
Next maintenance due
A
Motor protection signal
A
(bimetal contact of
pump) is active (open)
Sensor voltage too low
B
RTC has no valid time
A
information
Read error Flash
B
Write error Flash
B
Reprogramming error
B
Flash
Gas sensor defective
A
Signal during
A
measurement <4mA
Signal during
A
measurement >20mA
Several successive
A
small gas values during
measurement
Possible cause
• Maintenance date reached
• Pump overheated
• Printed circuit board defective
• Time setting has got lost after
prolonged disconnection from power
supply
• Hardware/software problem
• Hardware/software problem
• Hardware/software problem
• Malfunctions in measuring signal,
possible faulty cable connection to SCU
• Sensor not connected, cable damage
• Short-circuit in cable, signal too large
• Vent blocked/not working correctly
A N ecessary, reset possible within normal use
(control restarts after resetting).
B No duty, automatic reset within normal use.
Troubleshooting
• Carry out maintenance and enter
'Maintenance done' (Service menu)
• Check temperatures
• Check free running pump
• Replace control unit
• Enter time and date again
• Get in contact with service department
• Get in contact with service department
• Get in contact with service department
• Check connection to controller,
Exchange sensor if necessary
• Test cable connections, test vent
device, if necessary clean the filters
• Check and clean vent device
WILO 07/2018