Natural Gas; Gas Supply Hose - Broil King 956084 Manual Del Usuario

Ocultar thumbs Ver también para 956084:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION – FIXED PIPE LP OR NATURAL GAS LINE
GAS LINE LOCATION
LP Gas and Natural Gas supply lines should be installed by
a qualified professional.
Note: Provide access in the enclosure for gas supply and
regulator service.
Note: Area should be kept clear of sharp or abrasive
surfaces to avoid damage to gas supply lines. Exercise
caution when pulling gas lines through the built-in
enclosure.
SPECIFICATIONS FOR PIPING
Installation must use rigid pipe, semi-rigid tubing, or a
connector complying with the Standard for Connectors
for Outdoor Gas Appliances and Manufactured Homes,
ANSI Z21.75•CSA 6.27 and suitable for outside
installation
The gas connections must be firmly attached to rigid,
permanent construction
A 3/8 inch SAE 45 degree flare connection has been
provided. Do not use pipe sealant on this connection
A manual shut-off valve must be installed outdoors, and
be accessible from outside of the built in enclosure.
For bulk propane and natural gas, an additional indoor
manual shut-off valve should be installed in the branch
fuel line in an accessible location near the supply line
CONNECTION TO A REMOTE SELF
CONTAINED LP GAS SUPPLY
LP gas grills are designed to operate at a regulated
pressure of 11 inches water column
An in line LP pressure regulator suitable for bulk
propane installations is required to maintain 11
inches water column pressure. (not supplied)
The gas supply connection from the grill manifold to the
gas supply bulkhead must not exceed 72" (182cm)
When the grill is not in use, turn off the LP gas supply
at the shut off valve
CONNECTION TO NATURAL GAS
SUPPLY
If grill is designed for use with natural gas, do not use
with liquid propane (bottled gas). The valves, orifices,
and hoses are for natural gas only
Natural Gas Grills are designed to operate at a
regulated pressure of 7 inches water column
The gas supply hose from the grill manifold to the gas
supply bulkhead must not exceed 120" (305cm)
The gas must be turned off at the natural gas supply
when the barbecue is not in use
When the grill is not in use, turn off the natural gas
supply at the shut off valve
GAS SUPPLY TESTING
The outdoor gas grill and its individual shutoff valve
must be disconnected from the gas supply piping
system during any pressure testing of that system at
test pressures in excess of 1/2 psig (3.5kPa)
The outdoor gas grill must be isolated from the gas
supply piping system by closing its individual manual
shut off valve during any pressure testing of the gas
supply piping system at test pressures equal to or less
than 1/2 psig (3.5kPa)

GAS SUPPLY HOSE

On models supplied with an extension hose, the hose
assembly is specifically designed for your model. No
modifications or additions should be attempted. Hose
and hose couplings comply with CGA Standard CAN
1.83
On models equipped with the "quick disconnect"
coupling, close "shut off valve" before disconnecting
coupling
"Quick disconnect" coupling must be kept clean and
free of dirt and debris
Protect the hose from dripping grease and do not allow
the hose to touch any hot surface, including the base
casting of the barbecue
Inspect the hose at least once per year. If the hose is
cracked, cut, abraded or damaged, the appliance must
not be used
For replacement of hose assembly, contact your
dealer or approved service center
A.
GAS SUPPLY PIPING
B.
QUICK DISCONNECT COUPLING
C.
ADAPTER FITTING
D.
EXTENSION HOSE ASSEMBLY
12

Publicidad

Tabla de contenido
loading

Tabla de contenido