ENGLISH
You can inverse the behavior of one or more slave units by changing the position of DIP-switch n°10 on
these slaves. Just try it and see if the effect becomes better.
3. Connect the optional CA-8 controller for more control:
The CA-8 controller can only be used in standalone or master/slave mode. Connect the
controller to the jack input of the first unit (master). Now you can control all the connected
units:
Blackout the unit
Stand by
1. Synchronous Strobe
Function
2. Sound Strobe
3. Two light Strobe
Mode
Strobe (LED OFF)
4. DMX-mode:
When the units are connected in DMX-mode, they can be controlled using the following DMX-chart:
Two DMX-modes are available: 1CH and 6CH mode:
1 channel mode:
Extremely user friendly mode: you only need 1 DMX channel to choose 1 of the 12 preprogrammed
sound chases or you can use our Effect commander to switch the unit ON/OFF (no switch pack
needed).
6 channel mode:
You can take full control of all pre-programmed functions of the effect.
Channel 1: switch the unit on/off and select one of the 25 chases.
Channel 2: Control for the strobe function.
Channel 3: Control the output for the red LEDs.
Channel 4: Control the output for the green LEDs.
Channel 5: Control the output for the blue LEDs.
Channel 6: Control the output for the general dimmer.
1 CHANNEL MODE
JB SYSTEMS
®
OPERATION MANUAL
Select a show
Show (LED ON)
6 CHANNEL MODE
5/40
LED QUADRA BEAM
ENGLISH
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 30 days.
Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
AC 100V to 240V, 50/60Hz
Power consumption:
12 Watt
Fuse:
250V 6,3A slow blow (20mm glass)
Sound Control:
Internal microphone
DMX connections:
3pin XLR male / female
DMX channels used:
1 or 6 channels
Lamp:
256 LEDs (R96 + G96 + B64)
Size:
965 x 190 x 82cm
Weight:
6,4kg
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
JB SYSTEMS
®
OPERATION MANUAL
6/40
LED QUADRA BEAM