ReaderTamper
Ifthebackplateispulledawayfromthewall,thetamperplateremainsattachedtothe
wallandawalltamperconditionisgenerated.Likewise,ifthereaderisremovedfromthe
backplate,acasetamperconditionisgenerated.
ThevoltageontheTamperlineisnormallylow.Ifcasetamperorwalltamperisdetected,
thevoltageontheTamperlinebecomeshighandthereadersounds3longbeepsevery5
secondsfortwominutes,thenstops.
Toclearawalltampercondition,reattachthebackplatetothetamperplate.Toclearacase
tampercondition,reattachthereadertothebackplate.
Usage
LEDs
Red
Default
Sounder
•
Thereadersounds4rapidbeepswhenitispowereduporrestarted.
•
Ifspecified,thereaderbeepsoncewhenatokenispresented.
CableLengths
PAC /Sonitroldoorcontrollersonly
CableGauge
7/0.2 0.34mm² 22AWG
16/0.2 0.5mm² 20AWG
32/0.2 1.0mm² 18AWG
Green
Accesspermitted
DistancefromReadertoController
PAC2100/2200
750ft/250m
1500ft/500m
3000ft/1000m
8
Red/Green
Accessdenied
PAC202/512 /Sonitrol
230ft/70m*
230ft/70m*
230ft/70m*