Motion Sensor
Light Control
Model SH-5710
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
• Additional energy savings with compact fluorescent
bulbs.
This package includes:
Lamp Holders
Cover Plate
Light Control
Mounting Bolt
Mounting Strap
2 Compact
Fluorescent Bulbs
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
• Note: This product is not recommended for use where
the outside temperature is below -10° F.
© 2004 DESA Specialty Products™
Rubber Plug
Plastic Hanger
Sensor
2 Wire
Connectors
Gasket
6 Screws
(3 sizes included)
OPERATION
Mode:
On-Time:
Test
5 Sec
Auto
1, 5, 10 min.
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, or
10 minute position. Note: Although
the 1 minute mode can be used, the 5
or 10 minute mode is recommended
for best operation and performance
when using compact fluorescent bulbs.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
Works:
Day
x
1
/
minutes for
2
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second OFF
then ...
... back on.
Move ON-TIME Switch
to 1, 5, or 10 minutes
Flip light switch
off for one second
then back on*
598-1163-01
Night
x
x
x

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Secure Home SH-5710

  • Página 1 Manual Until Dawn* Light Control * resets to Auto Mode at dawn. Note: When first turned on wait about 1 minutes for Model SH-5710 the circuitry to calibrate. TEST Features • Turns on lighting when motion is detected. ON-TIME Put the ON-TIME switch on the bottom •...
  • Página 2: Wall Mount

    ❒ Route the Light Control’s wires through the large INSTALLATION gasket holes. For easy installation, select an existing light with a wall ❒ Twist the junction box wires and fixture wires together switch for replacement. as shown. Secure with wire connectors. Mounting Black to White to...
  • Página 3 ❒ Loosen the clamp screw in the TEST AND ADJUSTMENT Clamp sensor ball joint and gently ro- Screw ❒ Turn on the circuit breaker and light switch. tate the sensor. Ball ❒ Walk through the coverage area Joint NOTE: Sensor has about 1 minutes warm up period noting where you are when the before it will detect motion.
  • Página 4: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Lights will not come 1. Light switch is turned off. Lights stay on 1. A flood lamp is positioned too close to 2. Flood light loose continuously. the sensor or pointed at nearby ob- burned out.
  • Página 5: Control De Luz Del Detector De Movimiento

    Manual Hasta el detector de movimiento amanecer* *Se pone en Automático al amanecer. Modelo SH-5710 Nota: Cuando lo prenda por primera vez espere 1 Características minutos para que el circuito se claibre. • Prende la luz cuando detecta movimiento. Para PRUEBA: •...
  • Página 6: Instalacion

    ❒ Conecte los cables de la caja de empalme con los INSTALACION cables del aparato de luz, como se muestra. Tuérazalos Para una fácil instalación escoja una luz con un juntos y asegúrelos con un conector de cables. interruptor de pared. lámina de 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 Blanco a...
  • Página 7: Prueba Y Ajuste

    ❒ Afloje el tornillo sujetador en PRUEBA Y AJUSTE Tornillo la unión esférica y gire Sujetador ❒ Prenda el cortacircuitos y el interruptor de luz. despacio el detector. ❒ Camine por el área a Unión NOTA: El detector tiene un período de cerca de 1 protegerse y dése cuenta Esférica minutos de calentamiento antes de detectar...
  • Página 8: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA 1. El interruptor de luz está La luz se 1. Un faro está colocado demasiado cerca enciende. apagado. queda al detector o apunta a objetos cercanos 2. El faro está flojo o fundido. prendida que hace que el calor active el detector.

Tabla de contenido