StartingLine SLG-620 Manual De Funcionamiento página 3

Pistola pulverizadora por gravedad
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
READ BEFORE ATTACHING THE AIR HOSE
SET-UP AND ADJUSTMENT INSTRUCTIONS
1. Attach Cup to Gun and flush through with cleaning
solvent to remove oils.
2. Adjust packing nut (see packing adjustment
instructions).
3. Fully open fan and fluid needle controls (turn
counter-clockwise).
4. If desired, attach air adjusting valve with gauge
and/or quick disconnect to air inlet, then attach
hose. Recommended air pressure 2 bar (29 psi).
A failure resulting in injury or damage may be caused by pressure exceeding the maximum air of fluid
pressure, excessive vibration or pressure pulsation, excessive temperature, corrosion of the pressure
containing parts or other misuse of this spray gun.
OPERATION
1. Spray test an area. Turn the fluid needle adjusting
knob counter clockwise until a full coat is obtained.
2. If the finish is too sandy and dry, the material flow
may be too low for the atomising air pressure being
used. Turn the fluid needle adjusting knob counter
clockwise (out) to increase the fluid flow.
3. If the finish sags there is too much material flowing
for the atomisation air pressure being used. Turn
the fluid needle adjusting screw clockwise (in) to
decrease the fluid flow.
CLEANING
1. For routine cleaning, it is not necessary to remove
cup from gun. Remove lid and properly dispose of
any excess paint. Pour in a small amount of clean
solvent. The amount will vary with different
coatings and solvents. Reinstall lid. Shake cup to
wash down the inside surfaces. Pull trigger to
ATTENTION!
5. Spray test and adjust air pressure, fan size and fluid
flow as required. Recommended spray distance 6 –
8 inches (150—200mm).
6. Do not exceed maximum pressure of 4 bar (60psi)
for air pressure.
7. Ensure materials to be sprayed are compatible with
this spray gun.
WARNING
PACKING ADJUSTMENT INSTRUCTIONS
Before using this spray gun, the packing nut should be
adjusted as follows;
1. Tighten packing nut until fluid needle starts to bind in
the packing.
2. Loosen packing nut just enough so the fluid needle
moves freely.
The packing nut is intentionally left loose so the PTFE
packing does not take a "set" before the spray gun is
used. This allows full utilisation of the packing.
4. The pattern width can be altered by turning the fan
control clockwise (in) to decrease the width or
counter clockwise to increase the width.
5. Adjust the inlet air pressure to provide a uniform
dispersion of atomised paint throughout the pattern.
Keep the air pressure as low as possible to
minimise bounce-back and overspray. Excessive
pressure will result in split spray patterns.
Inadequate pressure will cause heavy centred
patterns and poor atomisation.
allow some solvent to be flushed through gun.
Remove lid and pour out dirty solvent. Add a small
amount of clean solvent and repeat procedure.
Wipe exterior of lid with a clean cloth and clean
solvent.
2. If a paint filter was used in the bottom of the cup
outlet, it should be removed and cleaned at this
time.
3
© 2014 Finishing Brands UK Ltd.