Drainage system
■ hammam
■ sauna + hammam
■ sauna + shower
Two drainage pipes are provided.
- We recommend connecting the two drainage pipes so that you
are left with one drainage outlet, as indicated in positions 1 or 1a.
It is also possible to independently connect the drainage pipes
to the drainage system.
■ hammam + shower
■ sauna + shower + hammam
Four drainage pipes are provided. (two for the "hammam" module
and two for the "shower" module).
- We recommend, with each module, connecting the drainage
pipes so that you are left with one drainage outlet, as indicated
in positions 1 or 1a.
It is also possible to independently connect the drainage pipes
to the drainage system.
In all cases, you must ensure that the drainage pipe fittings are
routed to the floor, as indicated, whilst bearing in mind the posi-
tioning of the frame supports (feet).
Hydraulic connections
■ For connection to the water supply (position 5D - shower; 5H -
hammam) we advise using pipes with min Ø 14 mm; these pipes
must have a 1/2" M pipe joint.
■ The "sauna" model is equipped with an automatic filling tank
which must be powered by a a 3/8" M (cold water) pipe joint (po-
sition 5S).
■ In order to ensure correct operation, the pressure and flow
rate values must also comply with the values specified in the rel-
evant "Hydraulic specifications".
Where "hard" water is present, it is advisable to install
a decalcifier in the water system supplying water to the
appliance, in order to reduce and/or avoid calcareous
deposits.
ATTENTION: (IEC 60335-1/A2) The pressure of the wa-
ter system supplying water to the appliance must not
exceed 600 k Pa (6 bar).
Electrical connections
■ The module "sauna" is equipped with a multiple-pole switch,
complete with a cable, approximately 400 cm in length, already con-
nected to the appliance's junction box, as indicated in position 2S.
This switch must be connected to an area that complies with the
safety regulations as specified by current legislation in force.
■ The module "hammam" is equipped with a quadripolar termi-
nal block, placed in the equipment zone; a cable must be con-
nected to this terminal block (position 2H) ; the aforementioned
cable must be connected to an isolating multi-pole switch;this
switch must be connected to an area that complies with the
safety regulations as specified by current legislation in force.
The steam generator, common to the "hammam" mod-
ule, can be supplied with absorbed power equal to 4.6
kW or 6 kW. If power is provided with a three-phase line
(380-415 V ) and you wish to limit the absorbed power
to 4.6 kW, the cable which is to be connected to the ter-
minal block should only have two phases, in addition
to the neutral and earth wires.
In the instance where the absorbed power is equal to
6 kW, power must be provided by three phases, in ad-
dition to the neutral and earth wires.
For guidance with regards to electrical connections,
please refer to the installation manual.
■ The module "shower" is equipped with a terminal block,
placed in the equipment zone; a cable must be connected to this
terminal block (position 2D) ; the aforementioned cable must be
connected to an isolating multi-pole switch;this switch must be
connected to an area that complies with the safety regulations
as specified by current legislation in force.
9