Wall-mounted EV charger

Safety instruction

Read the package leafl et carefully before using the wall-mounted EV charger. Not following the warnings and instructions below may result in fi re,
electric shock, serious injury, or death.
Wall-mounted EV chargers are intended only for charging of electric vehicles that support the IEC 62196-1 and IEC 61851-1 standards. Do not use
charging accessories for vehicles, that require ventilation during charging, or for any other purposes.
Do not use wall-mounted EV chargers with plugs that do not comply with regulations and standards.
Do not use the EV charger if it is damaged in any way or if the LED indicates a serious problem.
Never attempt to remove, modify or repair the wall-mounted EV chargers. In event of of malfunction, please refer to the user manual or contact the
dealer whom you bought it from.
Never disconnect the charging cable from the electric car during charging.
The wall-mounted EV charger must be always installed according to the legat requirements in the country of installation.
Do not expose the wall-mounted EV charger to external infl uences such as heavy rain or snow unnecessarily. Also, try to protect the wall-mounted
EV chargers from moisture and water.
Do not put infl ammable, explosives, combustible materials, chemicals, combustible steam and other dangerous articles near the wall-mounted EV
charger.
Never touch the end outlets with sharp objects or any diff erent tool.
Do not allow children and unauthorized people to handle the charging accessory. Because improper handling of the charger cable and its subsequent
use can result in electric shock, fi re, serious injury, or death.
Installation and connection of wall-mounted EV charger
1.
Install the wall-mounted EV charger directly into a plain wall in convenient position for operation and maintenance. Mounting instructions are at page 2.
In case of installation outside, the wall-mounted EV charger should be placed under a roof to avoid direct rain impact.
2.
Connect the inlet cable correctly to the wall-mounted EV charger according to wiring diagram at page 3/4. Inlet cable must be of appropriate dimensions
according to the maximum charging current and must be protected by appropriate circuit breaker at the superior switchboard. (NOTE: Electrical
installation must be done by qualifi ed person!)
3.
Turn ON the wall-mounted EV charger by opening the cover and switching ON the RCCB type B inside the charger (Ex9LB63).
4.
The self-testing procedure will start, status LED will lights in red, blue and green. Wait till status LED start fl ashing in blue color.
5.
If the procedure is correct, status LED will start fl ashing in blue color. Now you can connect the plug of wall-mounted EV charger into the electric
vehicle. Charging will start automatically.
Disconnection of the wall-mounted EV charger
1.
Firstly, stop the charging in the vehicle.
2.
Then you can disconnect the plug.
Never remove the plug during charging!

Problem Solving

In case of an early termination of charging, check the vehicle's on-board system
If a high temperature is the cause why charging stopped, disconnect the power cord and allow it to cool down
If the problem occurs repeatedly, it is necessary to check the connection of the plug, event. contact the seller
If there is a problem with the wall-mounted EV charger and the charger indicates it, disconnect it, take the necessary steps, and check the plug
connection if necessary
Signalling of LED diode
STATUS
The wall-mounted EV charger can indicate several conditions during charging or immediately
after turning ON the RCCB type B inside of EV charger. The explanation for possible states
is as following:
No light - No power / RCCB is switched off / RCCB tripped (leakuage
current issue)
Flashing blue - Charger is ready to connect
Solid blue - Car is connected, not charging
Solid green - Charging / fully charged
Solid red - High temperature, not charging (we recommend disconnecting
the charger)
Flashing red - Failure, not charging (check the car system / try to reconnect
the car)