Applicable to Field Installable Connectors.
To properly bend the cable:
•
Cable must NOT bent below the Minimum Bending Radius
Non-Bendable Length of 5cm near the connector end MUST be
adhered to.
•
Note the minimum bending radius for conductors > 1.5mm
•
Pull forces on the contact points can be avoided by bending
the wire as required.
(Minimum Bending Radius)
5cm
(Non-Bendable Length)
XB.AC.3106000 (for cable OD 6-10mm)
XB.AC.4006000 (for cable OD 10-14mm)
3-pin Field Installable AC Female Connector IP66
6-10mm/0.24"-0.4"
10-14mm/0.4"-0.55"
30mm/1.2"
8mm/0.3"
0.8 - 1.0 Nm
0.6 - 0.7 lb ft
XB.AC.2303000
5-pin Field Installable AC Female Connector IP66
(for cable OD 10-14mm)
10-14mm/0.4"-0.55"
30mm/1.2"
8mm/0.3"
0.8 - 1.0 Nm
0.6 - 0.7 lb ft
www.traxontechnologies.com
©2020 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE
WITHOUT NOTICE.
Mounting Guide
Do no put excessive force or
install connectors in a vibrating
environment.
A l l eg ro Was h er A C 1 0 0 W
Avoid vertical placement of the connectors.
If vertical installation is unavoidable:
•
Add
glue on the surface of cable gland.
silicone
•
Layout the cable to have drip loop to allow water run off
the wire.
2
.
Silicone Glue
XB.AC.2302000
5-pin Field Installable AC Male Connector IP66
(for cable OD 10-14mm)
10-14mm/0.4"-0.55"
30mm/1.2"
8mm/0.3"
0.8 - 1.0 Nm
0.6 - 0.7 lb ft
Remember to tighten cable gland after installation.
Make sure the cable gland also tighten the cable
sheath.
01/20 V0.4
M o u nt i n g Gu ide
Silicone Glue
3 of 4