Descargar Imprimir esta página

Monacor RMA-350 Manual De Instrucciones página 2

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 5
®
GB
Cable Remote Control for the
Camera TVCCD-350COL
1 Operating Elements and Connections
1 Numerical keys for numerical inputs;
e. g. to select the camera No. 35, press the following
buttons:
Cam.
, 3, 5,
Enter
2 Functional keys, see chapter 5
3 Buttons for zoom control
4 Buttons for tilting and panning the camera
5 POWER switch
6 Connection for the 12 V operating voltage;
a low voltage plug 5.5/2.1 mm (outside/inside diam-
eter) is required
7 RS-485 control line for connection of the cameras
2 Safety Notes
This unit corresponds to the directive 89/336/EEC for
electromagnetic compatibility.
The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity, and heat (admissible ambient temperature
range 0 – 40 °C).
For cleaning only use a dry, soft cloth, by no means
chemicals or water.
No guarantee claims for the unit and no liability for
any resulting personal damage or material damage
will be accepted if the unit is used for other purposes
than originally intended, if it is not correctly connect-
ed, operated, or not repaired in an expert way.
If the unit is to be put out of operation definitively, take
it to a local recycling plant for disposal which is not
harmful to the environment.
3 Applications
The remote control RMA-350 serves for the control of up
to 99 cameras of the model TVCCD-350COL. The
connection of the cameras is made via the RS-485 inter-
face with a cable length of 1200 m which is possible as
a maximum. For the power supply a regulated 12 V
power supply unit is required.
4 Making the Connections
1) The RS-485 control line (7) can be extended with a
twisted, 2-pole line to a length of 1200 m. Connect all
cameras in parallel to this control line. Connect the
red core of the cameras to the red core of the remote
control in each case. Connect the white cores corre-
spondingly.
2) For power supply, connect a regulated 12 V power
supply unit via a low voltage plug 5.5/2.1 mm (out-
side/inside diameter) to the inline jack (6). In any
case, pay attention to the polarity: Apply the positive
pole to the inside contact of the plug.
5 Operation
Switch on the remote control with the lateral sliding
switch (5). The display shows "00". To control a camera,
enter its address number first.
5.1 Entering the camera address
1) Press the button
. The display shows "CA".
Cam.
2) With the numerical keys (1) type the address (1 ... 99)
of the camera to be controlled. The display shows the
number.
3) Confirm the input with the button
ed camera can now be controlled. The following oper-
ating steps always refer to the selected camera only.
5.2 Tilting and panning the camera
Adjust the camera to the desired surveillance area with
the four arrow keys (4).
®
Copyright
RMA-350
1
2
5.3 Selecting the tilting and panning speed
1) Press the button
2) Select the speed with one of the numerical keys (1)
[button 1 = slow, button 0 = fast]:
Numerical key
Speed °/s
Display
It is not necessary to actuate the button
5.4 Zooming
Select the desired zoom adjustment with the button
Tele
or
Wide
5.5 Memorizing the camera positions
It is possible to memorize 64 different camera positions
which can subsequently be selected precisely.
1) Adjust the camera with the arrow keys (4) and select
the desired zoom adjustment with the button
or
(3).
Wide
2) Press the button
3) With the numerical keys (1) enter the number (1 – 64)
under which the position is to be memorized.
4) To memorize, press the button
5) To memorize further positions, repeat the operating
steps 1) to 4).
5.6 Cancelling the camera positions
To cancel a certain camera position:
1) Press the button
2) Enter the camera position to be cancelled with the
numerical keys (1).
3) To cancel, press the button
Cancelling all camera positions:
1) Press the button
"EA" (erase all).
2) To cancel, press the button
5.7 Precisely selecting the memorized positions
1) Press the button
. The select-
Enter
2) Enter the number of the desired position with the
numerical keys (1).
3) Press the button
5.8 Precisely selecting all positions automatically
All memorized positions can precisely be selected auto-
matically and continuously. (At least 2 positions have to
be memorized.)
1) Press the button
(sequence).
2) Start the sequence with the button
3) After 5 seconds respectively the unit goes to the next
position. For a longer dwell time, after pressing the
©
by MONACOR INTERNATIONAL GmbH & Co. KG, Bremen, Germany. All rights reserved.
Order No. 19.9730
®
Remote Control
1
2
3
4
5
6
Seq.
Auto
Goto
Speed
Tele
Cam.
Save
Erase
Enter
Wide
Stop
3
. The display shows "SP".
Speed
1
2
3
4
5
6
7
8
9 15 20 30 40 50 58 66 78 93
F1 F2 F3 F4 F5 F6 F7 F8 F9 F0
Enter
(3).
Save
. The display shows "SA".
Enter
.
. The display shows "Er".
Erase
.
Enter
twice. The display signalizes
Erase
.
Enter
. The display shows "Go".
Goto
.
Enter
. The display shows "Sq"
Seq.
Enter
.
DISPLAY
7
8
9
0
ON
POWER
OFF
4
5
button
Seq.
with the numerical keys (1), enter the
time in seconds (1 – 99) which is to elapse in addition
to the 5 seconds (max. 99 s + 5 s = 104 s). Start the
sequence with the button
4) To stop the sequence, press the button
9
0
The positions can also automatically be selected at ran-
dom. (At least 3 positions have to be memorized.)
1) Press the button
Seq.
(random). If necessary, enter a longer dwell time with
.
the numerical keys.
2) Start the sequence with the button
3) To stop the sequence, press the button
5.9 Continuous panning
For continuous panning of 350°:
Press the buttons
Auto
izes "AP" (auto panning).
For continuous panning between two defined positions:
Tele
1) Memorize the two desired positions (end points while
panning) as described under chapter 5.5.
2) Press the button
Auto
numerical keys (1) enter the number under which the
first end point has been memorized.
3) Press the button
Auto
the number of the other end point.
4) Start the panning with the button
For continuous panning, the speed is fixed to 20°/s. To
change the tilting angle, actuate the corresponding
arrow key (4), and to change the zoom adjustment the
button
Tele
or
Wide
(3). To stop the panning, press
the button
.
Enter
5.10 Reset of the camera to the initial position
In case the camera adjustment should have been
changed by a shock or disturbance during operation, it
is possible to make an initialization. For this purpose
press the button
Cam.
twice. The display shows "In".
Then press the button
approx. 16 s.
6 Specifications
Cameras to be controlled: . 99
Camera connection: . . . . . . RS-485 interface,
Power supply: . . . . . . . . . . . 12 V
Dimensions: . . . . . . . . . . . . 140 x 27 x 95 mm
Weight: . . . . . . . . . . . . . . . . 340 g
According to the manufacturer.
Subject to technical modifications.
®
12 V
RS-485
6
7
.
Enter
.
Enter
twice. The display shows "rA"
Enter
.
Enter
.
and
. The display signal-
Enter
(display "AP"). With the
again (display "to") and enter
Enter
.
. The initialization takes
Enter
red core = RS-485 A,
white core = RS-485 B,
cable length max. 1200 m
/100 mA
A-0234.99.01.05.2004

Publicidad

loading

Este manual también es adecuado para:

19.9730