ENGLISH
TECHNICAL DATA
Voltage (V)
Current (A)
Watts (W)
No load speed (rpm)
Blade diameter (mm)
Blade bore (mm)
Blade bore thickness
Max depth of cut (mm)
Weight (kg)
ELECTRICAL SAFETY
Be sure the supply is the same as the voltage given on the
rating plate. Your charger is fitted with a two-core cable
and plug.
MAINS PLUG REPLACEMENT
Should the mains plug or cordset of the product be
damaged, it must only be replaced by an authorised
Black & Decker service agent because special
purpose tools are required.
MAINS PLUG REPLACEMENT ON 1 HOUR CHARGER
(UK ONLY)
If you are using a 1 hour charger and the mains plug
needs replacing, and you are competent to do this,
proceed as instructed below.
If you are in doubt, contact a Black & Decker service
agent or a qualified electrician.
• Disconnect the plug from the power supply.
• Cut off the plug and dispose of safely. A plug with
bared copper conductors is very dangerous if
engaged in a live socket outlet.
• Only fit BS1363A approved plugs fitted with the
correctly rated fuse.
Note: Fuses do not give personal protection against
electric shock.
• The cable wire colours, or a letter, will be marked at
the connection point of most good quality plugs.
Attach the wires to their respective points in the
plug (see diagram). Brown is L (live) and blue is N
(neutral).
30
KC1440SK ML p27-34 ENG
KC1440SK
Fit a BS1363A
14.4
approved
resilient plug
min
2,200
Connect
mm
136
blue to
N (neutral)
mm
10
mm
1.1
mm
41
Make sure that the
3
outer sheath of the
cable is held firmly
by the clamp
• Before replacing the top cover of the plug ensure
that the cable restraint is holding the outer sheath of
the cable firmly and that the two leads are correctly
fixed at the terminal screws. If the fuse cover is
missing or damaged do not use the plug.
TECHNICAL DATA
The level of sound pressure of the tool is in accordance
with EEC legislation. It is recommended that you take
appropriate measures for the protection of your hearing
if the sound level seems uncomfortable. This normally
equates to a sound pressure in excess of 85dB (A).
Note: This user manual also covers catalogue numbers
ending with a letter suffix. Refer to your carton for
details of your product.
FEATURES
30
Fit a 5 amp fuse
E
L
N
230 volts AC only
Never use a light
1. Battery pack
2. On/off switch
3. Saw shoe
4. Riving knife
5. Guard retracting lever
6. Blade guard
7. Lock-off button
8. Front handle
9. Window Unlock spring
10. Window
11. Mitring angle scale
12. Locking screw for mitring adjustment
13. Sight guide
14. Mark for straight cut
15. Mark for mitring cut
16. Depth of cut adjustment
17. Blade
18. Depth of cut scale
19. Saw blade locking screw
30/3/00, 1:59 pm
approved
to BS1362
Connect
brown to
L (live)
socket