GB
Disconnect the CO
hose from the pressure regulator and briskly unscrew the pressure regulator anti-clockwise from the
2
cylinder fitting. This creates an initial hissing noise. Unscrew briskly until the fitting is detached from the cylinder. Dispose of
the empty cylinder according to the local regulations for waste disposal. Connect a new cylinder as described for u001.
Refillable storage cylinders:
Close the cylinder valve and disconnect the CO
hose from the pressure regulator. Open the adjusting screw (f) and release
2
any pressure remaining in the pressure regulator until the gauge shows 0. Disconnect the connecting nut (a) of the pressure
regulator fitting from the cylinder valve. Have the refillable cylinder refilled.
If no full refillable storage cylinders are available at the moment, a disposable cylinder can be used. Using an Allen key (size
6) remove the cylinder connection nut (a) from the pressure regulator fitting. The free thread fits disposable cylinders.
Connect the filled refillable cylinder or the disposable cylinder as described for m001 and u001.
Technical data:
JBL ProFlora u001 pressure regulator :
Cylinder connection thread: M10 x 1
Cylinder pressure gauge: 0-160 bar
Operating pressure gauge: 0- 4 bar
Adjustment screw for operating pressure
Precision needle valve
Connection thread for hose connection: 1/8"
Hose connection for hose 4/6 mm
JBL ProFlora m001 pressure regulator:
Hose connection thread W21.8x1/14"
All other data as for u001