ELECTRIC CONNECTION
The electrical connection must be made only by qualified personnel. It must be in compliance with
CEI requirements and specifications.
The unit must be connected to the mains only if between it and the mains there is an omnipolar
switch with at least 3 mm of opening between contacts for each pole. This must be in an easily
accessible position near the oven.
The available connections and the procedure for replacing the cable, if necessary, are described
below.
After carrying out the electrical connections, cover the terminal board as shown in the following
figure.
The connection cable must be at least type H07 RN-F. Fixed connections require the use of
conduits which must comply with standards.
The figure to the side shows the connection
terminal block of the oven. Fasten the cable in
the appropriate cable terminal and proceed
with the electrical wiring.
The wiring diagram below shows the possible
connections provided for the oven. According
to the power supply voltage, wire the oven by
installing the appropriate jumpers in the
positions indicated. Tighten the screws firmly
to prevent dangerous overheating.
Attention:
Electric Version Only
Not available with the Gas version
Connect the equipotential terminal to the grounding
system through the use of a conductor of at least 6mmq
of section.
Easy Series Ovens – Page 28
400V ~ 3PH + N + PE
1
2
3
4
5
6
L1
L2
L3
N
230V ~ 1PH + N + PE
1
2
3
4
5
6
N
L
400V ~ 2PH + N + PE
1
2
3
4
5
6
N
L1
L2
230V ~ 3PH + PE
1
2
3
4
5
6
L3
L1
L2
7
7
7
7