PAC 512 DC Guia De Inicio Rapido página 5

Controlador de acceso
Ocultar thumbs Ver también para 512 DC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
One Touch™ Test Mode
To speed up installation and testing, One-Touch™ testing is provided which allows the controller functionality to be tested at the controller
or reader.
Test
Action
Normal Operation
Hold down One-Touch™ button for less than 2
seconds. Present keys, press RTE switches and
One-Touch™ View
observe LEDs.
Mode
Automatically exits after 2 minutes.
One-Touch™ Active
Hold down One-Touch™ button for 2 to 4
Mode
seconds.
Present a key to each reader (the lock will
activate).
Reader and Request to
Press the Request to Exit switch (the lock will
Exit Test
activate).
Open the door contact.
Present a key to a reader, press the Request to Exit switch and open
the door contact simultaneously.
Auxiliary and Lock
Remove link to 0V on tamper or open circuit tamper switch.
Relays Test
Remove link to 0V on emergency override or leave open circuit
tamper switch.
Remove the link between TAMP and 0V on the Tamper & Override
terminal block.
Tamper and Override
Test
Remove the link between OVRD and 0V on the Tamper & Override
terminal block.
Hold down One-Touch™ button for less than 2
Leave One-Touch™
seconds. One-Touch™ Test mode will
Active Test mode
automatically be timed out after 1 hour, power
up or power down.
Observation
Controller
System status:
GREEN flashes at
normal rate.
Green
Door status:
All LEDs
off.
Green-Red-Yellow
System status
GREEN
flashes at normal rate.
Green
Door status:
GREEN
on, valid key presented
to reader.
Green-Red-Yellow
Door status:
GREEN
flashes, invalid key
presented to reader.
Green-Red-Yellow
Door status:
RED on,
door open.
Green-Red-Yellow
Door status:
YELLOW
on, RTE switch has
been pressed.
Green-Red-Yellow
System status:
GREEN flashes faster
than normal.
Green
Door status:
GREEN
flashes once for SIGA,
twice for SIGB.
Green-Red-Yellow
Door status:
GREEN
flashes three times
and YELLOW is on.
Green-Red-Yellow
Door status:
GREEN
flashes four times and
RED is on.
Green-Red-Yellow
The appropriate auxiliary relay is activated.
Both auxiliary relays are activated.
The auxiliary relay is activated.
The auxiliary relay is activated but the door relays are unaffected.
Both auxiliary and lock relays are activated, the door opens and the lock
operates.
System status:
GREEN flashes at
normal rate again.
Green
- 5 -
Reader
Normal operation of the reader.
Red
Normal operation of the reader LED
changes, e.g. if default is red it
changes to green.
Green
Reader LED flashes once for SIGA,
twice for SIGB.
Red
Reader LED flashes three times.
Red
Reader LED flashes four times.
Red
Reader LED returns to normal
operation.
Red

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

512 dci

Tabla de contenido